Literature DB >> 21621785

Using multiple short-end injections to develop fast electrophoretic separations--applications in iodide analysis.

Luciano Vitali1, Bethânia L Horst, Melina Heller, Valfredo T Fávere, Gustavo A Micke.   

Abstract

The aim of this study was to develop a fast CE separation method by using multiple short-end injections in a capillary coated with quaternary ammonium chitosan (HACC), in order to determine the iodide content of pharmaceutical formulations. The BGE was composed of 20 mM tris(hydroxymethyl)aminomethane and 11 mM hydrochloric acid, at pH 8. The internal standard used was thiocyanate. Separations were performed in a fused silica capillary (32 cm total length, 8.5 cm effective length and 50 μm i.d.) coated with HACC and direct UV detection at 220 nm. EOF was modified by flushing the capillary with polymeric solution, resulting in a semi-permanent coating of controlled and stable EOF. The EOF was anodic at pH 8. Different strategies, using single and multiple injection short-end configurations, were studied to develop a CE method that resulted in a maximum number of iodide samples analyzed per hour: one plug and flush (Sflush) 35 samples/h, one plug without flush (SWflush) 76 samples/h, four plugs and flush (Mflush) 61 samples/h, and four plugs without flush (MWflush) 80 samples/h. Using the multiple injection configuration, it was possible to inject up to four plugs using spacer electrolytes with good separation efficiency and selectivity. The voltage application time needed to separate the eight peaks (iodide and thiocyanate) with MWflush was only 12s. The method was validated and samples were analyzed using MWflush. Good linearity (R(2)>0.999); a limit of detection 0.4 mg L(-1); intermediate precision better than 3.8% (peak area) and recovery in the range of 99-102% were obtained.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21621785     DOI: 10.1016/j.chroma.2011.04.084

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Fluorenone-Based Fluorescent and Colorimetric Sensors for Selective Detection of I- Ions: Applications in HeLa Cell Imaging and Logic Gate.

Authors:  Hafiz Muhammad Junaid; Muhammad Tahir Waseem; Zulfiqar Ali Khan; Farhan Munir; Summar Sohail; Umar Farooq; Sohail Anjum Shahzad
Journal:  ACS Omega       Date:  2022-03-08

2.  High-Throughput Analysis of Lidocaine in Pharmaceutical Formulation by Capillary Zone Electrophoresis Using Multiple Injections in a Single Run.

Authors:  Andressa C Valese; Daniel A Spudeit; Maressa D Dolzan; Lizandra C Bretanha; Luciano Vitali; Gustavo A Micke
Journal:  J Anal Methods Chem       Date:  2016-03-16       Impact factor: 2.193