Literature DB >> 21621232

Assessment of the heat stability of seven rapid HIV assays.

Kate M Learmonth1, Chris Y Chiu, Hazel Galang, Mohammad J Nawang, Elizabeth M Dax.   

Abstract

Human Immunodeficiency Virus Rapid Diagnostic Tests (HIV RDTs) are robust, quick to perform, effective diagnostic tools. The stability of seven commonly used RDTs for detecting antibody to HIV was assessed during exposure to temperatures above 30°C, the usual maximum recommended by manufacturers. The aim of the study was to determine if HIV RDTs retain their testing outcomes after exposure to higher temperatures. At two testing sites, seven RDTs were exposed to a short heat shock (60°C for 72 hours) as might occur during transport. RDTs were exposed to ambient (22 or 30°C), warm (35 or 37°C) or hot (45°C) temperatures for up to 90 days. Testing was performed at five intervals on a panel of seven positive and three negative plasma samples. Results showed no changes consistent with altered testing outcomes over time and/or temperature when test indicators were compared with the control indicators. Only one HIV RDT achieved 100% consensus with reference results at all four storage temperatures (median 97.5%, lowest 74% for RDT5 at 45°C). Testing outcomes in a limited sample panel showed six of seven HIV RDT kits were relatively robust despite exposure to higher than recommended temperatures.
Copyright © 2011 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21621232     DOI: 10.1016/j.trstmh.2011.04.005

Source DB:  PubMed          Journal:  Trans R Soc Trop Med Hyg        ISSN: 0035-9203            Impact factor:   2.184


  3 in total

1.  A pilot external quality assurance study of transfusion screening for HIV, HCV and HBsAG in 12 African countries.

Authors:  E M Bloch; A Shah; Z Kaidarova; S Laperche; J-J Lefrere; J van Hasselt; P Zacharias; E L Murphy
Journal:  Vox Sang       Date:  2014-07-23       Impact factor: 2.144

2.  Temperature and the field stability of a dengue rapid diagnostic test in the tropics.

Authors:  Koukeo Phommasone; Onanong Sengvilaipaseuth; Xavier de Lamballerie; Manivanh Vongsouvath; Ooyanong Phonemixay; Stuart D Blacksell; Paul N Newton; Audrey Dubot-Pérès
Journal:  Am J Trop Med Hyg       Date:  2015-05-11       Impact factor: 2.345

3.  Temperature of a Dengue Rapid Diagnostic Test under Tropical Climatic Conditions: A Follow Up Study.

Authors:  Onanong Sengvilaipaseuth; Koukeo Phommasone; Xavier de Lamballerie; Manivanh Vongsouvath; Ooyanong Phonemixay; Stuart D Blacksell; Mayfong Mayxay; Sommay Keomany; Phoutthalavanh Souvannasing; Paul N Newton; Audrey Dubot-Pérès
Journal:  PLoS One       Date:  2017-01-27       Impact factor: 3.240

  3 in total