Comparison of near infrared and microwave resonance sensors for at-line moisture determination in powders and tablets.

Claudia C Corredor1, Dongsheng Bu, Douglas Both.   

Abstract

In this paper we demonstrate the feasibility of replacing KF for water content testing in bulk powders and tablets with at-line near infrared (NIR) or microwave resonance (MR) methods. Accurate NIR and MR prediction models were developed with a minimalistic approach to calibration. The NIR method can accurately predict water content in bulk powders in the range of 0.5-5% w/w. Results from this method were compared to a MR method. We demonstrated excellent agreement of both NIR and MR methods for powders vs. the reference KF method. These methods are applicable to in-process control or quality control environments. One of the aims of this study was to determine if a calibration developed for a particular product could be used to predict the water content of another product (with related composition) but containing a different active pharmaceutical ingredient (API). We demonstrated that, contrary to the NIR method, a general MR method can be used to predict water content in two different types of blends. Finally, we demonstrated that a MR method can be developed for at-line moisture determination in tablets.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21621036     DOI: 10.1016/j.aca.2011.03.048

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Accuracy Improvement of In-line Near-Infrared Spectroscopic Moisture Monitoring in a Fluidized Bed Drying Process.

Authors:  Andrey Bogomolov; Joachim Mannhardt; Oliver Heinzerling
Journal:  Front Chem       Date:  2018-10-10       Impact factor: 5.221

Review 2.  Model-Based Scale-Up Methodologies for Pharmaceutical Granulation.

Authors:  Eun Ha Jang; Yun Sang Park; Min-Soo Kim; Du Hyung Choi
Journal:  Pharmaceutics       Date:  2020-05-14       Impact factor: 6.321

Review 3.  Process Analytical Technology Tools for Monitoring Pharmaceutical Unit Operations: A Control Strategy for Continuous Process Verification.

Authors:  Eun Ji Kim; Ji Hyeon Kim; Min-Soo Kim; Seong Hoon Jeong; Du Hyung Choi
Journal:  Pharmaceutics       Date:  2021-06-21       Impact factor: 6.321

4.  Simple modification of karl-Fischer titration method for determination of water content in colored samples.

Authors:  Eva Tavčar; Erika Turk; Samo Kreft
Journal:  J Anal Methods Chem       Date:  2012-03-19       Impact factor: 2.193

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.