Jasper W van Keulen1, Jean-Paul P M de Vries, Hannah Dekker, Frederico B Gonçalves, Frans L Moll, Hence J Verhagen, Joost A van Herwaarden.   

Abstract

OBJECTIVE: The Endurant (Medtronic, Minneapolis, Minn) is a new stent graft specifically designed to make more patients anatomically eligible for endovascular aneurysm (EVAR). This study presents the 1-year results of 100 consecutive patients with abdominal aortic aneurysms (AAAs) treated with the Endurant stent graft in real-life practice.
METHODS: All clinical preoperative, operative, postoperative, and 1-year follow-up data of patients with the Endurant stent graft from three tertiary centers were prospectively collected. Patients underwent computed tomographic angiography (CTA) preoperatively, at 1 month, and at 1-year post-EVAR. The first 100 patients with an implantation date at least 1 year before our date of analysis and complete information were included. Clinical data, AAA characteristics, presence of endoleaks, graft migration, and other EVAR-related complications were noted. All values are stated as mean ± SD (range).
RESULTS: This study included 100 patients with AAAs (88 men) with a mean age of 73 ± 8 years (47 to 87 years), an AAA size of 61 ± 10 mm (31 to 93 mm), an AAA volume of 210 ± 122 mL (69 to 934 mL), a proximal neck length of 33 ± 14 mm (9 to 82 mm), and an infrarenal angulation of 44 ± 25° (0°-108°). Nineteen of the 100 included patients had at least one anatomic characteristic that was considered a violation of the instructions for use (IFU) of the Endurant stent graft. A primary technical success was achieved in 98% of the patients (one additional stent placement in renal artery was required; one unplanned aorto-uni-iliac device placed), with no primary type I or III endoleaks or conversions. A secondary technical success was achieved in all cases. The 30-day mortality was 2% and the first postoperative CTA documented 16 endoleaks (16%; 16 type II). One-year follow-up showed three iliac limb occlusions (3%), one infected stent graft (causing a type Ia endoleak), and five endovascular reinterventions (5%; three to treat iliac limb occlusions, one proximal extension cuff; and one stent in the renal artery). The 1-year all-cause mortality rate was 12% (12 patients) and the AAA-related mortality was 3%. The mean AAA size was significantly smaller after 1 year (diameter, 54 ± 11.8 [32-80] mm; P < .01; volume, 173 ± 119 [42-1028] mL; P < .01), and one graft migration >5 mm and 13 endoleaks were noted (12 type II, 1 type I [neck dilatation]).
CONCLUSION: The treatment of patients with AAAs with the Endurant stent graft seems to be successful and durable during the first year after EVAR. Despite the wider inclusion criteria for the Endurant, and with 19% of our patients treated outside the IFU, the AAA-related mortality, number of type I or III endoleaks, and reintervention rates are comparable to the results of other stent grafts.
Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21620631     DOI: 10.1016/j.jvs.2011.02.053

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  14 in total

1.  A real mycotic aneurysm-mycotic aneurysm of the abdominal aorta due to fungal infection.

Authors:  Deniz Tihan; Murat Aksoy
Journal:  Ulus Cerrahi Derg       Date:  2014-12-01

Review 2.  A critical appraisal of endovascular stent-grafts in the management of abdominal aortic aneurysms.

Authors:  Nikolaos Schoretsanitis; Efstratios Georgakarakos; Christos Argyriou; Kiriakos Ktenidis; George S Georgiadis
Journal:  Radiol Med       Date:  2017-01-21       Impact factor: 3.469

Review 3.  Surgical Versus Endovascular Aortic Aneurysm Repair: Evidence to Guide the Optimal Approach for the Individual Patient.

Authors:  Theodore Hart; Ross Milner
Journal:  Curr Atheroscler Rep       Date:  2016-12       Impact factor: 5.113

4.  Three-Year Results of the Endurant Stent Graft System Post Approval Study.

Authors:  Sarah E Deery; Katie E Shean; Alexander B Pothof; Thomas F X O'Donnell; Barbara A Dalebout; Jeremy D Darling; Thomas C F Bodewes; Marc L Schermerhorn
Journal:  Ann Vasc Surg       Date:  2018-03-02       Impact factor: 1.466

5.  A comparative study of the bell-bottom technique vs hypogastric exclusion for the treatment of aneurysmal extension to the iliac bifurcation.

Authors:  Peter A Naughton; Michael S Park; Elrasheid A H Kheirelseid; Sean M O'Neill; Heron E Rodriguez; Mark D Morasch; Prakash Madhavan; Mark K Eskandari
Journal:  J Vasc Surg       Date:  2012-01-05       Impact factor: 4.268

6.  Aneurysm sac expansion is independently associated with late mortality in patients treated with endovascular aneurysm repair.

Authors:  Sarah E Deery; Emel A Ergul; Marc L Schermerhorn; Jeffrey J Siracuse; Andres Schanzer; Philip P Goodney; Richard P Cambria; Virendra I Patel
Journal:  J Vasc Surg       Date:  2017-08-31       Impact factor: 4.268

7.  A novel measurement technique for the design of fenestrated stent grafts: Comparison with three-dimensional aorta models.

Authors:  Ji Hoon You; Sung-Gwon Kang; Bong Man Kim
Journal:  Exp Clin Cardiol       Date:  2013

Review 8.  A systematic review and meta-analysis indicates underreporting of renal dysfunction following endovascular aneurysm repair.

Authors:  Alan Karthikesalingam; Sandeep S Bahia; Shaneel R Patel; Bilal Azhar; Dan Jackson; Lynne Cresswell; Robert J Hinchliffe; Peter J E Holt; Matt M Thompson
Journal:  Kidney Int       Date:  2014-08-20       Impact factor: 10.612

9.  Technical and clinical outcome of Talent versus Endurant endografts for endovascular aortic aneurysm repair.

Authors:  Birger Mensel; Jens-Peter Kühn; Tobias Träger; Martin Dührkoop; Wolfram von Bernstorff; Christian Rosenberg; Andreas Hoene; Ralf Puls
Journal:  PLoS One       Date:  2012-06-08       Impact factor: 3.240

10.  Periaortic pedicle screw removal with endovascular control of the aorta and intraoperative aortography: a case report and review of the literature.

Authors:  Michael Q Potter; Brandon D Lawrence; Daniel V Kinikini; Darrel S Brodke
Journal:  Evid Based Spine Care J       Date:  2013-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.