Literature DB >> 21619255

Continuous-Flow System for On-Line Water Monitoring Using Back-Side Contact ISFET-Based Sensors.

C Jiménez1, I Marqués, J Bartrolí.   

Abstract

A multiparametric continuous-flow system for on-line monitoring of water based on ISFET sensors is described. The ISFETs used have silicon nitride as gate material, and the electrical contacts are placed on the back side of the chip. This is a technological improvement that allows for a more compact ISFET packaging and greatly increases the lifetime of the sensor compared with planar type ISFETs, since the electrical parts are separated from the chemical environment. A special probe has been designed in order to encapsulate and apply these ISFETs into the flow system. Further, a reference electrode based on standard Ag/AgCl technology has been constructed according to the ISFET probe design in order to integrate both sensors in the same flow-through cell. These probes can be easily replaced in the flow system and are made of cheap and easily mechanized materials. Using these flow-through sensors, a continuous-flow system for the determination of pH, NH(4)(+), Ca(2+), and NO(3)(-) in waters has been designed. The system configuration is based on a modular design (one setup for each parameter and a common sampling channel), which allows simple manipulation and maintenance as well as a good flexibility for different analytical requirements. A study of the system characteristics was performed by following the specifications for water monitoring. Under the conditions established for the flow system, a sampling rate of 20 h(-)(1) was obtained for each parameter, and long-term stabilities of at least 3 weeks of daily work for ISFET sensors and 5 months for the reference electrode have been achieved. The response performances obtained show the feasibility of the BSC ISFET probe use in continuous-flow monitoring.

Entities:  

Year:  1996        PMID: 21619255     DOI: 10.1021/ac9603946

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

Review 1.  ISFET based microsensors for environmental monitoring.

Authors:  Cecilia Jimenez-Jorquera; Jahir Orozco; Antoni Baldi
Journal:  Sensors (Basel)       Date:  2009-12-24       Impact factor: 3.576

Review 2.  Forward-Looking Roadmaps for Long-Term Continuous Water Quality Monitoring: Bottlenecks, Innovations, and Prospects in a Critical Review.

Authors:  Yuankai Huang; Xingyu Wang; Wenjun Xiang; Tianbao Wang; Clifford Otis; Logan Sarge; Yu Lei; Baikun Li
Journal:  Environ Sci Technol       Date:  2022-04-20       Impact factor: 11.357

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.