Literature DB >> 21619131

Dynamics and performance of fast linear scan anodic stripping voltammetry of cd, pb, and cu using in situ-generated ultrathin mercury films.

H P Wu1.   

Abstract

The dynamics of fast linear scan (LS) ASV for the simultaneous detection of Cd, Pb, and Cu was investigated at various scan rates (0.5-10 V/s) and at different metal ion concentrations (50-800 nM) utilizing ultrathin mercury films (9 nm) at a conventional size (d(0) = 1 mm) electrode. Results of the investigation show that when the thin films were utilized, diffusion of metals through the mercury film was not the rate-limiting step of the stripping process at moderate to fast scan rates (0.5-10 V/s). A fairly linear relationship between the peak height and scan rate was observed at scan rates (0.5-10 V/s) beyond the upper limit of the theoretical model for the behavior of LS-ASV. In addition, peak width at half-height (b(1/2)) as low as 33 mV was achieved at 0.5 V/s. The behavior of LS-ASV in terms of peak width at these scan rates is thus different from what the theoretical model of LS-ASV would have predicted. For the ultrathin mercury films, at least two additional factors, kinetics and concentration, have significant effects on practical LS-ASV. Experimental results show that the stripping process of Cu was primarily kinetic-controlled for fast scans, while those for Cd and Pb were dependent on both scan rates and concentrations. The ultrathin mercury film resulted in a significant enhancement of the ratio of signal-to-baseline slope (i(p)/Δi(b), a ratio used to measure the effectiveness of discrimination of the peak signal against the steep sloping baseline in LS-ASV) for Cd and Pb stripping peaks, but only a slight enhancement for Cu stripping peaks. The optimal performance of LS-ASV in terms of sensitivity, peak width, and enhancement of the i(p)/Δi(b) ratio for the three metals was achieved at 2 V/s. Because of the high reproducibility of the background currents of the stable in situ MTFs, background subtraction was carried out at 2 V/s with little hysteresis. This feature, combined with the enhancement of the i(p)/Δi(b) ratio at the fast scan rate of 2 V/s, allowed for the detection of sub-ppb levels of Cd, Pb, and Cu at a deposition time of 2 min.

Entities:  

Year:  1996        PMID: 21619131     DOI: 10.1021/ac950879e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Voltammetric trace determination of mercury using plant refuse modified carbon paste electrodes.

Authors:  Harsha Devnani; Soami Piara Satsangee
Journal:  Environ Monit Assess       Date:  2013-05-25       Impact factor: 2.513

2.  Metallo-graphene nanocomposite electrocatalytic platform for the determination of toxic metal ions.

Authors:  Chandre M Willemse; Khotso Tlhomelang; Nazeem Jahed; Priscilla G Baker; Emmanuel I Iwuoha
Journal:  Sensors (Basel)       Date:  2011-04-01       Impact factor: 3.576

3.  Colorimetric and fluorescent probes for real-time naked eye sensing of copper ion in solution and on paper substrate.

Authors:  Dugang Chen; Pengyu Chen; Luyi Zong; Yimin Sun; Guangchao Liu; Xianglin Yu; Jingui Qin
Journal:  R Soc Open Sci       Date:  2017-11-08       Impact factor: 2.963

Review 4.  Paper-Based Microfluidics for Electrochemical Applications.

Authors:  Liu-Liu Shen; Gui-Rong Zhang; Bastian J M Etzold
Journal:  ChemElectroChem       Date:  2019-11-18       Impact factor: 4.590

5.  Modifier-Free Microfluidic Electrochemical Sensor for Heavy-Metal Detection.

Authors:  Liu-Liu Shen; Gui-Rong Zhang; Wei Li; Markus Biesalski; Bastian J M Etzold
Journal:  ACS Omega       Date:  2017-08-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.