Literature DB >> 21618258

Experience with local lymph node assay performance standards using standard radioactivity and nonradioactive cell count measurements.

David Basketter1, Susanne N Kolle, Arnhild Schrage, Naveed Honarvar, Armin O Gamer, Bennard van Ravenzwaay, Robert Landsiedel.   

Abstract

The local lymph node assay (LLNA) is the preferred test for identification of skin-sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. To facilitate acceptance of nonradioactive variants, validation authorities have published harmonized minimum performance standards (PS) that the alternative endpoint assay must meet. In the present work, these standards were applied to a variant of the LLNA based on lymph node cell counts (LNCC) run in parallel as a control with the standard LLNA with radioactivity measurements, with threshold concentrations (EC3) being determined for the sensitizers. Of the 22 PS chemicals tested in this study, 21 yielded the same results from standard radioactivity and cell count measurements; only 2-mercaptobenzothiazole was positive by LLNA but negative by LNCC. Of the 16 PS positives, 15 were positive by LLNA and 14 by LNCC; methylmethacrylate was not identified as sensitizer by either of the measurements. Two of the six PS negatives tested negative in our study by both LLNA and LNCC. Of the four PS negatives which were positive in our study, chlorobenzene and methyl salicylate were tested at higher concentrations than the published PS, whereas the corresponding concentrations resulted in consistent negative results. Methylmethacrylate and nickel chloride tested positive within the concentration range used for the published PS. The results indicate cell counts and radioactive measurements are in good accordance within the same LLNA using the 22 PS test substances. Comparisons with the published PS results may, however, require balanced analysis rather than a simple checklist approach.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21618258     DOI: 10.1002/jat.1684

Source DB:  PubMed          Journal:  J Appl Toxicol        ISSN: 0260-437X            Impact factor:   3.446


  3 in total

1.  Local lymph node assay: 5-bromo-d-deoxyuridine-ELISA method for comparative study in assessing chemical potencies and skin sensitization in BALB/c and CBA/J strains.

Authors:  Jeong-Ja Oh; Eun-Sung Park; Seong-Sook Kim; Min-Seung Lee; Woo-Joo Lee; Bum-Su Pak; Min-Sub Kim; Hyun-Kul Lee; Si-Whan Song; Sun-Don Kim
Journal:  Toxicol Rep       Date:  2022-03-21

2.  Accounting for Precision Uncertainty of Toxicity Testing: Methods to Define Borderline Ranges and Implications for Hazard Assessment of Chemicals.

Authors:  Silke Gabbert; Miriam Mathea; Susanne N Kolle; Robert Landsiedel
Journal:  Risk Anal       Date:  2020-12-09       Impact factor: 4.302

3.  Nickel: Intrinsic Skin Sensitization Potency and Relation to Prevalence of Contact Allergy.

Authors:  David Basketter
Journal:  Dermatitis       Date:  2021 Mar-Apr 01       Impact factor: 4.867

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.