Literature DB >> 21616944

Clinical applications of magnets on cardiac rhythm management devices.

Sony Jacob1, Sidakpal S Panaich, Rahul Maheshwari, John W Haddad, Benzy J Padanilam, Sinoj K John.   

Abstract

The growing indications for permanent pacemaker and implantable cardioverter defibrillator (ICD) implantation have increased the number of patients with these cardiac rhythm management devices (CRMDs). Cardiac rhythm management devices occasionally perform inappropriately in response to electromagnetic interference (e.g. surgical electrocautery) or lead noise over-sensing (e.g. lead fracture). Temporary reprogramming of the CRMDs using device programmers can prevent these untoward device responses. However, these programmers are device manufacturer specific and require technically qualified personnel to operate. This could cause delayed patient care and increased use of resources in certain clinical situations. Alternatively, clinical magnets, when appropriately positioned over the device site, can change the pacing to an asynchronous mode in pacemakers and suspend tachycardia therapies in ICDs. Although readily available, clinical magnets have not been widely used for this purpose, perhaps due to the unfamiliarity with the variable responses of CRMDs to magnet application. This article provides a comprehensive overview of the current literature on the mechanism of action and the specific responses of various CRMDs to clinical magnets.

Entities:  

Mesh:

Year:  2011        PMID: 21616944     DOI: 10.1093/europace/eur137

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  19 in total

Review 1.  A practical approach to perioperative management of cardiac implantable electronic devices.

Authors:  Pow-Li Chia; David Foo
Journal:  Singapore Med J       Date:  2015-10       Impact factor: 1.858

Review 2.  [What must intensive care physicians know about implantable cardioverter defibrillator?].

Authors:  E Gatterer
Journal:  Med Klin Intensivmed Notfmed       Date:  2013-09-20       Impact factor: 0.840

3.  Incidence of magnet mode in patients with implantable cardioverter defibrillators.

Authors:  Gesa von Olshausen; Johanna Schorr; Christian Grebmer; Severin Weigand; Patrick Blažek; Amir Brkic; Lena Friedrich; Verena Semmler; Christof Kolb; Carsten Lennerz
Journal:  J Interv Card Electrophysiol       Date:  2019-10-16       Impact factor: 1.900

4.  3rd Guideline for Perioperative Cardiovascular Evaluation of the Brazilian Society of Cardiology.

Authors:  Danielle Menosi Gualandro; Pai Ching Yu; Bruno Caramelli; André Coelho Marques; Daniela Calderaro; Luciana Savoy Fornari; Claudio Pinho; Alina Coutinho Rodrigues Feitosa; Carisi Anne Polanczyk; Carlos Eduardo Rochitte; Carlos Jardim; Carolina L Z Vieira; Debora Y M Nakamura; Denise Iezzi; Dirk Schreen; Eduardo Leal Adam; Elbio Antonio D'Amico; Emerson Q de Lima; Emmanuel de Almeida Burdmann; Enrique Indalecio Pachón Mateo; Fabiana Goulart Marcondes Braga; Fabio S Machado; Flavio J de Paula; Gabriel Assis Lopes do Carmo; Gilson Soares Feitosa-Filho; Gustavo Faibischew Prado; Heno Ferreira Lopes; João R C Fernandes; José J G de Lima; Luciana Sacilotto; Luciano Ferreira Drager; Luciano Janussi Vacanti; Luis Eduardo Paim Rohde; Luis F L Prada; Luis Henrique Wolff Gowdak; Marcelo Luiz Campos Vieira; Maristela Camargo Monachini; Milena Frota Macatrão-Costa; Milena Ribeiro Paixão; Mucio Tavares de Oliveira; Patricia Cury; Paula R Villaça; Pedro Silvio Farsky; Rinaldo F Siciliano; Roberto Henrique Heinisch; Rogerio Souza; Sandra F M Gualandro; Tarso Augusto Duenhas Accorsi; Wilson Mathias
Journal:  Arq Bras Cardiol       Date:  2017 Jan-Feb       Impact factor: 2.000

5. 

Authors:  André Arpad Faludi; Maria Cristina de Oliveira Izar; José Francisco Kerr Saraiva; Ana Paula Marte Chacra; Henrique Tria Bianco; Abrahão Afiune; Adriana Bertolami; Alexandre C Pereira; Ana Maria Lottenberg; Andrei C Sposito; Antonio Carlos Palandri Chagas; Antonio Casella; Antônio Felipe Simão; Aristóteles Comte de Alencar; Bruno Caramelli; Carlos Costa Magalhães; Carlos Eduardo Negrão; Carlos Eduardo Dos Santos Ferreira; Carlos Scherr; Claudine Maria Alves Feio; Cristiane Kovacs; Daniel Branco de Araújo; Daniel Magnoni; Daniela Calderaro; Danielle Menosi Gualandro; Edgard Pessoa de Mello; Elizabeth Regina Giunco Alexandre; Emília Inoue Sato; Emilio Hideyuki Moriguchi; Fabiana Hanna Rached; Fábio César Dos Santos; Fernando Henpin Yue Cesena; Francisco Antonio Helfenstein Fonseca; Henrique Andrade Rodrigues da Fonseca; Hermes Toros Xavier; Isabela Cardoso Pimentel Mota; Isabela de Carlos Back Giuliano; Jaqueline Scholz Issa; Jayme Diament; João Bosco Pesquero; José Ernesto Dos Santos; José Rocha Faria; José Xavier de Melo; Juliana Tieko Kato; Kerginaldo Paulo Torres; Marcelo Chiara Bertolami; Marcelo Heitor Vieira Assad; Márcio Hiroshi Miname; Marileia Scartezini; Neusa Assumpta Forti; Otávio Rizzi Coelho; Raul Cavalcante Maranhão; Raul Dias Dos Santos; Renato Jorge Alves; Roberta Lara Cassani; Roberto Tadeu Barcellos Betti; Tales de Carvalho; Tânia Leme da Rocha Martinez; Viviane Zorzanelli Rocha Giraldez; Wilson Salgado
Journal:  Arq Bras Cardiol       Date:  2017-07       Impact factor: 2.000

Review 6.  Management of cardiac implantable electronic devices during interventional pulmonology procedures.

Authors:  Abhishek Kumar; Samjot Singh Dhillon; Spandan Patel; Matthias Grube; Amit Noheria
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

7.  Correlation of geomagnetic activity with implantable cardioverter defibrillator shocks and antitachycardia pacing.

Authors:  Elisa Ebrille; Tomas Konecny; Dana Konecny; Radim Spacek; Paul Jones; Pavel Ambroz; Christopher V DeSimone; Brian D Powell; David L Hayes; Paul A Friedman; Samuel J Asirvatham
Journal:  Mayo Clin Proc       Date:  2015-02       Impact factor: 7.616

8.  Electromagnetic interference in implantable cardioverter defibrillators: present but rare.

Authors:  Gesa von Olshausen; Ina-Christine Rondak; Carsten Lennerz; Verena Semmler; Christian Grebmer; Tilko Reents; Sonia Ammar-Busch; Alessandra Buiatti; Felix Bourier; Isabel Deisenhofer; Christof Kolb
Journal:  Clin Res Cardiol       Date:  2016-01-29       Impact factor: 5.460

9.  Routine issuance of clinical magnets to patients receiving implantable defibrillators: retention of information and appropriateness of use.

Authors:  Dewi E Thomas; James P Barry; Wendy Churchouse; Mark H Anderson
Journal:  Open Heart       Date:  2015-05-20

10.  iPad2(R) use in patients with implantable cardioverter defibrillators causes electromagnetic interference: the EMIT Study.

Authors:  Teri M Kozik; Gianna Chien; Therese F Connolly; Gurinder S Grewal; David Liang; Walter Chien
Journal:  J Am Heart Assoc       Date:  2014-04-10       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.