Literature DB >> 21616649

Carbon nanotube-chitosan modified disposable pencil graphite electrode for vitamin B12 analysis.

Filiz Kuralay1, Tayfun Vural, Cem Bayram, Emir Baki Denkbas, Serdar Abaci.   

Abstract

A single walled carbon nanotube-chitosan (SWCNT-chitosan) modified disposable pencil graphite electrode (PGE) was used in this study for the electrochemical detection of Vitamin B(12). Electrochemical behaviors of SWCNT-chitosan PGE and chitosan modified PGE were compared by using cyclic voltammetry (CV), square-wave voltammetry (SWV) and electrochemical impedance spectroscopy (EIS) techniques. SWCNT-chitosan modified electrode was also used for the quantification of Vitamin B(12) in pharmaceutical products. The results show that this electrode system is suitable for sensitive Vitamin B(12) analysis giving good recovery results. The surface morphologies of the SWCNT-chitosan PGE, chitosan modified PGE and unmodified PGE were characterized by using scanning electron microscopy (SEM).
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21616649     DOI: 10.1016/j.colsurfb.2011.03.030

Source DB:  PubMed          Journal:  Colloids Surf B Biointerfaces        ISSN: 0927-7765            Impact factor:   5.268


  6 in total

Review 1.  Recent advances in polymeric materials used as electron mediators and immobilizing matrices in developing enzyme electrodes.

Authors:  Mambo Moyo; Jonathan O Okonkwo; Nana M Agyei
Journal:  Sensors (Basel)       Date:  2012-01-16       Impact factor: 3.576

2.  Fabrication of novel electrochemical sensors based on modification with different polymorphs of MnO2 nanoparticles. Application to furosemide analysis in pharmaceutical and urine samples.

Authors:  Mohamed I Said; Azza H Rageh; Fatma A M Abdel-Aal
Journal:  RSC Adv       Date:  2018-05-23       Impact factor: 4.036

Review 3.  Pencil Graphite Electrodes: A Versatile Tool in Electroanalysis.

Authors:  Iulia Gabriela David; Dana-Elena Popa; Mihaela Buleandra
Journal:  J Anal Methods Chem       Date:  2017-01-31       Impact factor: 2.193

Review 4.  Polymers and Plastics Modified Electrodes for Biosensors: A Review.

Authors:  Sonia Lanzalaco; Brenda G Molina
Journal:  Molecules       Date:  2020-05-24       Impact factor: 4.411

Review 5.  Advances in Medical Wearable Biosensors: Design, Fabrication and Materials Strategies in Healthcare Monitoring.

Authors:  Sangeeth Pillai; Akshaya Upadhyay; Darren Sayson; Bich Hong Nguyen; Simon D Tran
Journal:  Molecules       Date:  2021-12-28       Impact factor: 4.411

6.  Development of a Novel, Low-Cost, Disposable Wooden Pencil Graphite Electrode for Use in the Determination of Antioxidants and Other Biological Compounds.

Authors:  James Kariuki; Emily Ervin; Carly Olafson
Journal:  Sensors (Basel)       Date:  2015-07-31       Impact factor: 3.576

  6 in total