Literature DB >> 21616594

Local characteristics of cross-unit contamination around high-rise building due to wind effect: mean concentration and infection risk assessment.

X P Liu1, J L Niu, K C S Kwok, J H Wang, B Z Li.   

Abstract

In this present work, the characteristics of hazardous gas dispersion and possible cross-unit contamination around a complex-shaped high-rise residential building due to wind effect are thoroughly studied using physical modeling method. Experiments were performed in a boundary layer wind tunnel for a 1:30 scale model that represented a 10-story residential building in prototype. Tracer gas, simulating exhausted room air, was continuously released from different floor levels, and its concentrations on the adjacent envelope surfaces were measured using fast flame ionization detectors. The mean concentration fields were reported and analyzed under different configurations during the experiment to consider the effects on pollutant dispersion behavior due to changes in source position and approaching wind condition, with the main emphasis on the differences between open-window and closed-window conditions. In particular, the measured concentration fields were further examined from a practical point of view, with respect to hazard assessment. Understanding these hazardous plume dispersion features is useful for employing effective intervention strategies in modern residential building environment in case of hazardous substance release. The study on this physical process is not only helpful to reduce the hazardous effect of routine release of harmful pollutant near the building, but also useful for the purpose of prevention and control of accidental infectious diseases outbreak.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21616594     DOI: 10.1016/j.jhazmat.2011.04.106

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  10 in total

1.  Transmission of pathogen-laden expiratory droplets in a coach bus.

Authors:  Xia Yang; Cuiyun Ou; Hongyu Yang; Li Liu; Tie Song; Min Kang; Hualiang Lin; Jian Hang
Journal:  J Hazard Mater       Date:  2020-04-12       Impact factor: 10.588

2.  The impact of building surface temperature rise on airflow and cross-contamination around high-rise building.

Authors:  Xiaoping Liu; Xiaojiao Wu; Mei Wu; Congling Shi
Journal:  Environ Sci Pollut Res Int       Date:  2020-01-24       Impact factor: 4.223

3.  Role of pathogen-laden expiratory droplet dispersion and natural ventilation explaining a COVID-19 outbreak in a coach bus.

Authors:  Qiqi Luo; Cuiyun Ou; Jian Hang; Zhiwen Luo; Hongyu Yang; Xia Yang; Xuelin Zhang; Yuguo Li; Xiaodan Fan
Journal:  Build Environ       Date:  2022-05-21       Impact factor: 7.093

4.  Large eddy simulation of wind-induced interunit dispersion around multistory buildings.

Authors:  Z T Ai; C M Mak
Journal:  Indoor Air       Date:  2015-04-07       Impact factor: 5.770

5.  Analysis of concentration fluctuations in gas dispersion around high-rise building for different incident wind directions.

Authors:  X P Liu; J L Niu; K C S Kwok
Journal:  J Hazard Mater       Date:  2011-07-06       Impact factor: 10.588

6.  Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part A: Effect of wind direction.

Authors:  Di Mu; Naiping Gao; Tong Zhu
Journal:  Build Environ       Date:  2016-08-30       Impact factor: 6.456

7.  Effect of pollutant source location on air pollutant dispersion around a high-rise building.

Authors:  Erfan Keshavarzian; Ruizhi Jin; Kejun Dong; Kenny C S Kwok; Yu Zhang; Ming Zhao
Journal:  Appl Math Model       Date:  2020-01-15       Impact factor: 5.129

8.  CFD investigation on the effects of wind and thermal wall-flow on pollutant transmission in a high-rise building.

Authors:  Di Mu; Naiping Gao; Tong Zhu
Journal:  Build Environ       Date:  2018-04-01       Impact factor: 6.456

Review 9.  The airborne transmission of infection between flats in high-rise residential buildings: A review.

Authors:  Jiachen Mao; Naiping Gao
Journal:  Build Environ       Date:  2015-09-30       Impact factor: 6.456

10.  Gaseous pollutant transmission through windows between vertical floors in a multistory building with natural ventilation.

Authors:  Jihong Wang; Tengfei Zhang; Shugang Wang; Francine Battaglia
Journal:  Energy Build       Date:  2017-08-12       Impact factor: 5.879

  10 in total