Literature DB >> 21615503

The prevalence and incidence of sick building syndrome in Chinese pupils in relation to the school environment: a two-year follow-up study.

X Zhang1, Z Zhao, T Nordquist, D Norback.   

Abstract

UNLABELLED: There are few incidence studies on sick building syndrome (SBS). We studied two-year change of SBS in Chinese pupils in relation to parental asthma/allergy (heredity), own atopy, classroom temperature, relative humidity (RH), absolute humidity (AH), crowdedness, CO₂, NO₂, and SO₂. A total of 1993 participated at baseline, and 1143 stayed in the same classrooms after two years. The prevalence of mucosal and general symptoms was 33% and 28% at baseline and increased during follow-up (P < 0.001). Twenty-seven percent reported at least one symptom improved when away from school. Heredity and own atopy were predictors of SBS at baseline and incidence of SBS. At baseline, SO₂ was associated with general symptoms (OR=1.10 per 100 μg/m³), mucosal symptoms (OR=1.12 per 100 μg/m³), and skin symptoms (OR=1.16 per 100 μg/m³). NO₂ was associated with mucosal symptoms (OR=1.13 per 10 μg/m³), and symptoms improved when away from school (OR=1.13 per 10 μg/m³). Temperature, RH, AH, and CO₂ were negatively associated with prevalence of SBS. Incidence or remission of SBS was not related to any exposure, except a negative association between SO₂ and new skin symptoms. In conclusion, heredity and atopy are related to incidence and prevalence of SBS, but the role of the measured exposures for SBS is more unclear. PRACTICAL IMPLICATIONS: We found high levels of CO₂ indicating inadequate ventilation and high levels of SO₂ and NO₂, both indoors and outdoors. All schools had natural ventilation, only. Relying on window opening as a tool for ventilation in China is difficult because increased ventilation will decrease the level of CO₂ but increase the level of NO₂ and SO₂ indoors. Prevalence studies of sick building syndrome (SBS) might not be conclusive for causal relationships, and more longitudinal studies on SBS are needed both in China and other parts of the world. The concept of mechanical ventilation and air filtration should be introduced in the schools, and when planning new schools, locations close to heavily trafficked roads should be avoided.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21615503     DOI: 10.1111/j.1600-0668.2011.00726.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  7 in total

1.  Particle size distribution and air pollution patterns in three urban environments in Xi'an, China.

Authors:  Xinyi Niu; Benjamin Guinot; Junji Cao; Hongmei Xu; Jian Sun
Journal:  Environ Geochem Health       Date:  2014-12-13       Impact factor: 4.609

2.  Sick building syndrome (SBS) and sick house syndrome (SHS) in relation to psychosocial stress at work in the Swedish workforce.

Authors:  Roma Runeson-Broberg; Dan Norbäck
Journal:  Int Arch Occup Environ Health       Date:  2012-11-11       Impact factor: 3.015

3.  A longitudinal study of sick building syndrome (SBS) among pupils in relation to SO2, NO2, O3 and PM10 in schools in China.

Authors:  Xin Zhang; Fan Li; Li Zhang; Zhuohui Zhao; Dan Norback
Journal:  PLoS One       Date:  2014-11-14       Impact factor: 3.240

4.  Synthesis of zeolitic imidazolate framework-8 on polyester fiber for PM2.5 removal.

Authors:  Yongyong Zhang; Ying Jia; Li'an Hou
Journal:  RSC Adv       Date:  2018-09-07       Impact factor: 4.036

5.  Rhinitis, Ocular, Throat and Dermal Symptoms, Headache and Tiredness among Students in Schools from Johor Bahru, Malaysia: Associations with Fungal DNA and Mycotoxins in Classroom Dust.

Authors:  Dan Norbäck; Jamal Hisham Hashim; Gui-Hong Cai; Zailina Hashim; Faridah Ali; Erica Bloom; Lennart Larsson
Journal:  PLoS One       Date:  2016-02-01       Impact factor: 3.240

6.  Sick Building Syndrome Among Junior High School Students in Japan in Relation to the Home and School Environment.

Authors:  Motoko Takaoka; Kyoko Suzuki; Dan Norbäck
Journal:  Glob J Health Sci       Date:  2015-06-12

7.  Investigation on Indoor Air Pollution and Childhood Allergies in Households in Six Chinese Cities by Subjective Survey and Field Measurements.

Authors:  Jinhua Hu; Nianping Li; Yang Lv; Jing Liu; Jingchao Xie; Huibo Zhang
Journal:  Int J Environ Res Public Health       Date:  2017-08-29       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.