Literature DB >> 21615143

Sensitive gas analysis system on a microchip and application for on-site monitoring of NH3 in a clean room.

Shinichiro Hiki1, Kazuma Mawatari, Arata Aota, Maki Saito, Takehiko Kitamori.   

Abstract

A portable, highly sensitive, and continuous ammonia gas monitoring system was developed with a microfluidic chip. The system consists of a main unit, a gas pumping unit, and a computer which serves as an operation console. The size of the system is 45 cm width × 30 cm depth × 30 cm height, and the portable system was realized. A highly efficient and stable extraction method was developed by utilizing an annular gas/liquid laminar flow. In addition, a stable gas/liquid separation method with a PTFE membrane was developed by arranging a fluidic network in three dimensions to achieve almost zero dead volume at the gas/liquid extraction part. The extraction rate was almost 100% with a liquid flow rate of 3.5 μL/min and a gas flow rate of 100 mL/min (contact time of ~15 ms), and the concentration factor was 200 times by calculating the NH(3) concentration (w/w unit) in the gas and liquid phases. Stable phase separation and detection was sustained for more than 3 weeks in an automated operation, which was sufficient for the monitoring application. The lower limit of detection calculated based on a signal-to-noise ratio of 3 was 84 ppt, which showed good detectability for NH(3) analysis. We believe that our system is a very powerful tool for gas analysis due to the advantages of portable size, high sensitivity, and continuous monitoring, and it is particularly useful in the semiconductor field.

Entities:  

Year:  2011        PMID: 21615143     DOI: 10.1021/ac200884z

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Micro total analysis systems: fundamental advances and applications in the laboratory, clinic, and field.

Authors:  Michelle L Kovarik; Douglas M Ornoff; Adam T Melvin; Nicholas C Dobes; Yuli Wang; Alexandra J Dickinson; Philip C Gach; Pavak K Shah; Nancy L Allbritton
Journal:  Anal Chem       Date:  2012-12-04       Impact factor: 6.986

Review 2.  Micro total analysis systems for cell biology and biochemical assays.

Authors:  Michelle L Kovarik; Philip C Gach; Douglas M Ornoff; Yuli Wang; Joseph Balowski; Lila Farrag; Nancy L Allbritton
Journal:  Anal Chem       Date:  2011-10-21       Impact factor: 6.986

3.  Large-Scale Integration of All-Glass Valves on a Microfluidic Device.

Authors:  Yaxiaer Yalikun; Yo Tanaka
Journal:  Micromachines (Basel)       Date:  2016-05-06       Impact factor: 2.891

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.