Effect of dislodging forces on mandibular implant attachment-retained overdenture.

Maha Wagdy Elkerdawy1, Iman Abdel Wahab Radi.   

Abstract

OBJECTIVES: : The goal of this in vitro study was to evaluate stress patterns and retention of ball and socket and 2 telescopic attachments of different convergence angles retaining an implant-supported overdenture prosthesis.
MATERIALS AND METHODS: : This study was carried out on an edentulous mandibular acrylic resin educational model. Four dummy implants, 3.5 mm in diameter and 11 mm in length, were installed in the interforaminal area. The framework of the overdenture was cast. Eight strain gauges were attached to the buccal and distal surfaces of all implants. The experiment was divided into 3 phases: 1 with the ball and socket attachment and the other with the angle 4 degrees followed by angle 6 degrees telescopic retainers. Once retention and stress analysis studies were completed for the ball attachments, they were replaced by the telescopic retainers. The universal testing machine was used to measure the retentive forces of the studied attachments. A 4-channel strain-meter was used to record the microstrains transmitted to each strain gauge while the machine was adjusted to move in a tensile mode.
RESULTS: : Statistical analysis showed the highest significant retention values for the ball and socket followed by telescope angle 4 degrees and finally angle 6 degrees. The same ranking was found on comparing the mean strains developed at the implants.
CONCLUSION: : This study has demonstrated that implant overdenture attachment design and dislodging forces may significantly influence stress/strain magnitude around implants; the higher the retention (resistance to dislodging forces) of the attachments the more the transferred stresses.

Mesh:

Substances:

Year:  2011        PMID: 21613951     DOI: 10.1097/ID.0b013e318211fe1b

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  2 in total

1.  Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial.

Authors:  M Y Sharaf; Asharaf Eskander; Mohamed Afify Afify
Journal:  Int J Dent       Date:  2022-02-28

2.  A Comparison of Biomechanical Properties of Implant-Retained Overdenture Based on Precision Attachment Type.

Authors:  Małgorzata Idzior-Haufa; Agnieszka A Pilarska; Wiesław Hędzelek; Piotr Boniecki; Krzysztof Pilarski; Barbara Dorocka-Bobkowska
Journal:  Materials (Basel)       Date:  2021-05-17       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.