Literature DB >> 21612144

Three-dimensional magnetic resonance image of structures enclosed in the spinal canal relevant to anesthetists and estimation of the lumbosacral CSF volume.

A Puigdellívol-Sánchez1, A Prats-Galino, M A Reina, F Machés, J M Hernández, J De Andrés, A van Zundert.   

Abstract

Three-dimensional (3D) image-reconstruction of structures inside the spinal canal certainly produces relevant data of interest in regional anesthesia. Nowadays, all hospital MRI equipment is designed mainly for clinical diagnostic purposes. In order to overcome the limitations we have produced more accurate images of structures contained inside the spinal canal using different software, validating our quantitative results with those obtained with standard hospital MRI equipment. Neuroanatomical 3D reconstruction using Amira software, including detailed manual edition was compared with semi-automatic 3D segmentation for CSF volume calculations by commonly available software linked to the MR equipment (MR hospital). Axial sections from seven patients were grouped in two aligned blocks (T1 Fast Field Eco 3D and T2 Balance Fast Field Eco 3D-resolution 0,65 x 0,65 x 0,65 mm, 130 mm length, 400 sections per case). T2 weighted was used for CSF volume estimations. The selected program allowed us to reconstruct 3D images of human vertebrae, dural sac, epidural fat, CSF and nerve roots. The CSF volume, including the amount contained inside nerve roots, was calculated. Different segmentation thresholds were used, but the CSF volume estimations showed high correlation between both teams (Pearson coefficient = 0.98, p = 0.003 for lower blocks; Pearson 0.89, p = 0.042 for upper blocks). The mean estimated value of CSF volume in lower blocks (L3-S1) was 15.8 + 2.9 ml (Amira software) and 13.1 +/- 1.9 ml (software linked to the MR equipment) and in upper blocks (T11-L2) was 21 +/- 4.47 ml and 18.9 +/- 3.5 ml, respectively. A high variability was detected among cases, without correlation with either weight, height or body mass index. Aspects concerning the partial volume effect are also discussed. Quick semi-automatic hospital 3D reconstructions give results close to detailed neuroanatomical 3D reconstruction and could be used in the future for individual quantification of lumbosacral CSF volumes and other structures for anesthetic purposes.

Entities:  

Mesh:

Year:  2011        PMID: 21612144

Source DB:  PubMed          Journal:  Acta Anaesthesiol Belg        ISSN: 0001-5164


  4 in total

1.  A method for quantitative measurement of lumbar intervertebral disc structures: an intra- and inter-rater agreement and reliability study.

Authors:  Andreas Tunset; Per Kjaer; Shadi Samir Chreiteh; Tue Secher Jensen
Journal:  Chiropr Man Therap       Date:  2013-08-16

2.  A 3D subject-specific model of the spinal subarachnoid space with anatomically realistic ventral and dorsal spinal cord nerve rootlets.

Authors:  Lucas R Sass; Mohammadreza Khani; Gabryel Connely Natividad; R Shane Tubbs; Olivier Baledent; Bryn A Martin
Journal:  Fluids Barriers CNS       Date:  2017-12-19

3.  Relationship Between Body Mass Index and Spread of Spinal Anesthsia in Pregnant Women: A Randomized Controlled Trial.

Authors:  Huai-Zhen Wang; Han-Wen Chen; Yan-Ting Fan; Yu-Ling Jing; Xing-Rong Song; Ying-Jun She
Journal:  Med Sci Monit       Date:  2018-09-04

Review 4.  Intrathecal Drug Delivery: Advances and Applications in the Management of Chronic Pain Patient.

Authors:  Jose De Andres; Salim Hayek; Christophe Perruchoud; Melinda M Lawrence; Miguel Angel Reina; Carmen De Andres-Serrano; Ruben Rubio-Haro; Mathew Hunt; Tony L Yaksh
Journal:  Front Pain Res (Lausanne)       Date:  2022-06-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.