Literature DB >> 21610293

Validation of an online replanning technique for prostate adaptive radiotherapy.

Cheng Peng1, Guangpei Chen, Ergun Ahunbay, Dian Wang, Colleen Lawton, X Allen Li.   

Abstract

We have previously developed an online adaptive replanning technique to rapidly adapt the original plan according to daily CT. This paper reports the quality assurance (QA) developments in its clinical implementation for prostate cancer patients. A series of pre-clinical validation tests were carried out to verify the overall accuracy and consistency of the online replanning procedure. These tests include (a) phantom measurements of 22 individual patient adaptive plans to verify their accuracy and deliverability and (b) efficiency and applicability of the online replanning process. A four-step QA procedure was established to ensure the safe and accurate delivery of an adaptive plan, including (1) offline phantom measurement of the original plan, (2) online independent monitor unit (MU) calculation for a redundancy check, (3) online verification of plan-data transfer using an in-house software and (4) offline validation of actually delivered beam parameters. The pre-clinical validations demonstrate that the newly implemented online replanning technique is dosimetrically accurate and practically efficient. The four-step QA procedure is capable of identifying possible errors in the process of online adaptive radiotherapy and to ensure the safe and accurate delivery of the adaptive plans. Based on the success of this work, the online replanning technique has been used in the clinic to correct for interfractional changes during the prostate radiation therapy.

Entities:  

Mesh:

Year:  2011        PMID: 21610293     DOI: 10.1088/0031-9155/56/12/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Process-based quality management for clinical implementation of adaptive radiotherapy.

Authors:  Camille E Noel; Lakshmi Santanam; Parag J Parikh; Sasa Mutic
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

2.  Learning statistical correlation for fast prostate registration in image-guided radiotherapy.

Authors:  Yonghong Shi; Shu Liao; Dinggang Shen
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  An Automated knowledge-based planning routine for stereotactic body radiotherapy of peripheral lung tumors via DCA-based volumetric modulated arc therapy.

Authors:  Justin Visak; Gary Y Ge; Ronald C McGarry; Marcus Randall; Damodar Pokhrel
Journal:  J Appl Clin Med Phys       Date:  2020-12-03       Impact factor: 2.102

4.  What benefit could be derived from on-line adaptive prostate radiotherapy using rectal diameter as a predictor of motion?

Authors:  Richard Oates; Suki Gill; Farshad Foroudi; Michael Lim Joon; Michal Schneider; Mathias Bressel; Tomas Kron
Journal:  J Med Phys       Date:  2015 Jan-Mar

5.  Diode-based transmission detector for IMRT delivery monitoring: a validation study.

Authors:  Taoran Li; Q Jackie Wu; Thomas Matzen; Fang-Fang Yin; Jennifer C O'Daniel
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.