Monitoring of HTS compound library quality via a high-resolution image acquisition and processing instrument.

Pierre Baillargeon1, Louis Scampavia, Ross Einsteder, Peter Hodder.   

Abstract

This report presents the high-resolution image acquisition and processing instrument for compound management applications (HIAPI-CM). The HIAPI-CM combines imaging spectroscopy and machine-vision analysis to perform rapid assessment of high-throughput screening (HTS) compound library quality. It has been customized to detect and classify typical artifacts found in HTS compound library microtiter plates (MTPs). These artifacts include (1) insufficient volume of liquid compound sample, (2) compound precipitation, and (3) colored compounds that interfere with HTS assay detection format readout. The HIAPI-CM is also configured to automatically query and compare its analysis results to data stored in a LIMS or corporate database, aiding in the detection of compound registration errors. To demonstrate its capabilities, several compound plates (n=5760 wells total) containing different artifacts were measured via automated HIAPI-CM analysis, and results compared with those obtained by manual (visual) inspection. In all cases, the instrument demonstrated high fidelity (99.8% empty wells; 100.1% filled wells; 94.4% for partially filled wells; 94.0% for wells containing colored compounds), and in the case of precipitate detection, the HIAPI-CM results significantly exceeded the fidelity of visual observations (220.0%). As described, the HIAPI-CM allows for noninvasive, nondestructive MTP assessment with a diagnostic throughput of about 1min per plate, reducing analytical expenses and improving the quality and stewardship of HTS compound libraries.
Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21609702      PMCID: PMC3417353          DOI: 10.1016/j.jala.2011.02.004

Source DB:  PubMed          Journal:  J Lab Autom        ISSN: 2211-0682


  8 in total

Review 1.  Application of high-throughput screening techniques to drug discovery.

Authors:  B Cox; J C Denyer; A Binnie; M C Donnelly; B Evans; D V Green; J A Lewis; T H Mander; A T Merritt; M J Valler; S P Watson
Journal:  Prog Med Chem       Date:  2000

2.  Compound library management.

Authors:  James A Chan; Juan A Hueso-Rodríguez
Journal:  Methods Mol Biol       Date:  2002

3.  Studies on repository compound stability in DMSO under various conditions.

Authors:  Xueheng Cheng; Jill Hochlowski; Hua Tang; Darlene Hepp; Carl Beckner; Stan Kantor; Robert Schmitt
Journal:  J Biomol Screen       Date:  2003-06

4.  The effect of freeze/thaw cycles on the stability of compounds in DMSO.

Authors:  Barbara A Kozikowski; Thomas M Burt; Debra A Tirey; Lisa E Williams; Barbara R Kuzmak; David T Stanton; Kenneth L Morand; Sandra L Nelson
Journal:  J Biomol Screen       Date:  2003-04

Review 5.  Acoustic auditing as a real-time, non-invasive quality control process for both source and assay plates.

Authors:  Joseph Olechno; Richard Ellson; Brent Browning; Richard Stearns; Mitchell Mutz; Michael Travis; Shehrzad Qureshi; Jean Shieh
Journal:  Assay Drug Dev Technol       Date:  2005-08       Impact factor: 1.738

6.  Evaluation and comparison of very high pressure liquid chromatography systems for the separation and validation of pharmaceutical compounds.

Authors:  Jennifer M Cunliffe; Sharee B Adams-Hall; Todd D Maloney
Journal:  J Sep Sci       Date:  2007-05       Impact factor: 3.645

7.  Compound Management for Quantitative High-Throughput Screening.

Authors:  Adam Yasgar; Paul Shinn; Ajit Jadhav; Douglas Auld; Sam Michael; Wei Zheng; Christopher P Austin; James Inglese; Anton Simeonov
Journal:  JALA Charlottesv Va       Date:  2008-04

8.  A high-throughput screening method for the determination of aqueous drug solubility using laser nephelometry in microtiter plates.

Authors:  C D Bevan; R S Lloyd
Journal:  Anal Chem       Date:  2000-04-15       Impact factor: 6.986

  8 in total
  4 in total

Review 1.  Targeting Phenotypically Tolerant Mycobacterium tuberculosis.

Authors:  Ben Gold; Carl Nathan
Journal:  Microbiol Spectr       Date:  2017-01

2.  Advanced Development of Primary Pancreatic Organoid Tumor Models for High-Throughput Phenotypic Drug Screening.

Authors:  Shurong Hou; Hervé Tiriac; Banu Priya Sridharan; Louis Scampavia; Franck Madoux; Jan Seldin; Glauco R Souza; Donald Watson; David Tuveson; Timothy P Spicer
Journal:  SLAS Discov       Date:  2018-04-19       Impact factor: 3.341

3.  The Scripps Molecular Screening Center and Translational Research Institute.

Authors:  Pierre Baillargeon; Virneliz Fernandez-Vega; Banu Priya Sridharan; Steven Brown; Patrick R Griffin; Hugh Rosen; Benjamin Cravatt; Louis Scampavia; Timothy P Spicer
Journal:  SLAS Discov       Date:  2019-01-25       Impact factor: 3.341

4.  A Rapid Phenotypic Whole-Cell Screening Approach for the Identification of Small-Molecule Inhibitors That Counter β-Lactamase Resistance in Pseudomonas aeruginosa.

Authors:  Deanna Collia; Thomas D Bannister; Hao Tan; Shouguang Jin; Taimour Langaee; Justin Shumate; Louis Scampavia; Timothy P Spicer
Journal:  SLAS Discov       Date:  2017-08-29       Impact factor: 3.341

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.