Abstract
The present study was oriented to prepare new scintillating anion-exchange resins for measurement of (99)TcO(4)(-) in natural waters. The organic fluor 2-(1-naphthyl)-5-phenyloxazole was diffused into (chloromethyl)polystyrene resin. Thereafter, a thin layer of poly[[2-(methacryloyloxy)ethyl]trimethylammonium chloride] was grafted from the resin surface by surface-initiated atom transfer radical polymerization as an attempt to overcome potential problems related to the leaching of fluor molecules during usage. The residual chloromethyl groups of the polymer-coated resin were aminated by reaction with two different tertiary amines, triethylamine (TEA) and methyldioctylamine (MDOA). Off- and on-line quantification of (99)Tc was achieved with high detection efficiencies of 60.72 ± 1.93% and 72.83 ± 0.81% for resin with TEA and MDOA functional groups, respectively. The detection limit was determined to be less than the maximum contaminant level (33 Bq L(-1)) established under the Safe Drinking Water Act. The two functionalized resins were demonstrated to be selective for pertechnetate from synthetic groundwater containing up to 1000 ppm Cl(-), SO(4)(2-), and HCO(3)(-) and up to 1200 ppb Cr(2)O(7)(2-) in an acidic medium.Entities: