Literature DB >> 21608027

B0 mapping with multi-channel RF coils at high field.

Simon Robinson1, Jorge Jovicich.   

Abstract

Mapping the static magnetic field via the phase evolution over gradient echo scans acquired at two or more echo times is an established method. A number of possibilities exist, however, for combining phase data from multi-channel coils, denoising and thresholding field maps for high field applications. Three methods for combining phase images when no body/volume coil is available are tested: (i) Hermitian product, (ii) phase-matching over channels, and (iii) a new approach based on calculating separate field maps for each channel. The separate channel method is shown to yield field maps with higher signal-to-noise ratio than the Hermitian product and phase-matching methods and fewer unwrapping errors at low signal-to-noise ratio. Separate channel combination also allows unreliable voxels to be identified via the standard deviation over channels, which is found to be the most effective means of denoising field maps. Tests were performed using multichannel coils with between 8 and 32 channels at 3 T, 4 T, and 7 T. For application in the correction of distortions in echo-planar images, a formulation is proposed for reducing the local gradient of field maps to eliminate signal pile-up or swapping artifacts. Field maps calculated using these techniques, implemented in a freely available MATLAB toolbox, provide the basis for an effective correction for echo-planar imaging distortions at high fields.
Copyright © 2011 Wiley-Liss, Inc.

Mesh:

Year:  2011        PMID: 21608027     DOI: 10.1002/mrm.22879

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Physiologic noise regression, motion regression, and TOAST dynamic field correction in complex-valued fMRI time series.

Authors:  Andrew D Hahn; Daniel B Rowe
Journal:  Neuroimage       Date:  2011-10-07       Impact factor: 6.556

2.  Rapid multi-orientation quantitative susceptibility mapping.

Authors:  Berkin Bilgic; Luke Xie; Russell Dibb; Christian Langkammer; Aysegul Mutluay; Huihui Ye; Jonathan R Polimeni; Jean Augustinack; Chunlei Liu; Lawrence L Wald; Kawin Setsompop
Journal:  Neuroimage       Date:  2015-08-12       Impact factor: 6.556

3.  Correction of B 0-induced geometric distortion variations in prospective motion correction for 7T MRI.

Authors:  Uten Yarach; Chaiya Luengviriya; Daniel Stucht; Frank Godenschweger; Peter Schulze; Oliver Speck
Journal:  MAGMA       Date:  2016-02-09       Impact factor: 2.310

4.  UCEPR: Ultrafast localized CEST-spectroscopy with PRESS in phantoms and in vivo.

Authors:  Zheng Liu; Ivan E Dimitrov; Robert E Lenkinski; Asghar Hajibeigi; Elena Vinogradov
Journal:  Magn Reson Med       Date:  2015-05-29       Impact factor: 4.668

5.  A method for unwrapping highly wrapped multi-echo phase images at very high field: UMPIRE.

Authors:  Simon Robinson; Horst Schödl; Siegfried Trattnig
Journal:  Magn Reson Med       Date:  2013-07-30       Impact factor: 4.668

6.  Joint B0 and image estimation integrated with model based reconstruction for field map update and distortion correction in prostate diffusion MRI.

Authors:  Muhammad Usman; Lebina Kakkar; Antonis Matakos; Alex Kirkham; Simon Arridge; David Atkinson
Journal:  Magn Reson Imaging       Date:  2019-10-23       Impact factor: 2.546

7.  The clinical relevance of distortion correction in presurgical fMRI at 7T.

Authors:  Pedro Lima Cardoso; Barbara Dymerska; Beáta Bachratá; Florian Ph S Fischmeister; Nina Mahr; Eva Matt; Siegfried Trattnig; Roland Beisteiner; Simon Daniel Robinson
Journal:  Neuroimage       Date:  2016-12-25       Impact factor: 6.556

8.  Differential functional benefits of ultra highfield MR systems within the language network.

Authors:  A Geißler; E Matt; F Fischmeister; M Wurnig; B Dymerska; E Knosp; M Feucht; S Trattnig; E Auff; W T Fitch; S Robinson; R Beisteiner
Journal:  Neuroimage       Date:  2014-09-22       Impact factor: 6.556

9.  Applying independent component analysis to clinical FMRI at 7 t.

Authors:  Simon Daniel Robinson; Veronika Schöpf; Pedro Cardoso; Alexander Geissler; Florian Ph S Fischmeister; Moritz Wurnig; Siegfried Trattnig; Roland Beisteiner
Journal:  Front Hum Neurosci       Date:  2013-09-02       Impact factor: 3.169

10.  Correcting dynamic distortions in 7T echo planar imaging using a jittered echo time sequence.

Authors:  Barbara Dymerska; Benedikt A Poser; Wolfgang Bogner; Eelke Visser; Korbinian Eckstein; Pedro Cardoso; Markus Barth; Siegfried Trattnig; Simon D Robinson
Journal:  Magn Reson Med       Date:  2015-11-19       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.