Literature DB >> 21606302

Perfusion CT of head and neck cancer: effect of arterial input selection.

Ahmed M Tawfik1, Ahmed A Abdel Razek, Lamiaa G Elsorogy, Nermin Y Soliman, J Matthias Kerl, Martin G Mack, Thomas J Vogl.   

Abstract

OBJECTIVE: The purpose of this study is to evaluate the effect of arterial input selection on perfusion CT parameters of head and neck tumors.
MATERIALS AND METHODS: Perfusion calculations were done for 50 cases using deconvolution-based software. Peak enhancement values of the ipsilateral internal carotid artery (ICA) and external carotid artery (ECA) were recorded. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface area product were calculated using ipsilateral ECA, ipsilateral ICA, and contralateral ICA as input arteries. Values were compared using Wilcoxon's matched pair test and Pearson's correlation coefficients (r).
RESULTS: A highly significant correlation was observed between peak enhancement values of the ICA and ECA (r = 0.97; p < 0.0001). A high correlation was observed between perfusion calculations obtained using ipsilateral ICA and ECA (BF, r = 0.98; BV, r = 0.92; MTT, r = 0.91; and permeability surface area product, r = 0.89), ipsilateral and contralateral ICA (BF, r = 0.97; BV, r = 0.95; MTT, r = 0.93; and permeability surface area product, r = 0.89), as well as left and right ICA (BF, r = 0.97; BV, r = 0.95; MTT, r = 0.94; and permeability surface area product, r = 0.88). All correlations were statistically significant (p < 0.0001). No significant differences were observed between perfusion calculations obtained using ipsilateral ICA versus ECA, ipsilateral versus contralateral ICA, or left versus right ICA (p > 0.05).
CONCLUSION: Arterial input selection has no significant effect on perfusion CT calculation of head and neck cancer. For standardization and simplification of postprocessing, we recommend the use of the ICA instead of the ECA as the arterial input because of its better visualization, perpendicular course, and larger caliber, all of which decrease partial volume effects.

Entities:  

Mesh:

Year:  2011        PMID: 21606302     DOI: 10.2214/AJR.10.5343

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

Review 1.  Computed tomography and magnetic resonance imaging of lesions at masticator space.

Authors:  Ahmed Abdel Khalek Abdel Razek
Journal:  Jpn J Radiol       Date:  2014-02-06       Impact factor: 2.374

2.  Diagnostic value of CT perfusion imaging for parotid neoplasms.

Authors:  Y Dong; G-W Lei; S-W Wang; S-W Zheng; Y Ge; F-c Wei
Journal:  Dentomaxillofac Radiol       Date:  2013-11-01       Impact factor: 2.419

Review 3.  Role of CT perfusion in monitoring and prediction of response to therapy of head and neck squamous cell carcinoma.

Authors:  Lorenzo Preda; Sonia Francesca Calloni; Marco Elvio Manlio Moscatelli; Maria Cossu Rocca; Massimo Bellomi
Journal:  Biomed Res Int       Date:  2014-07-21       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.