An evaluation of the A&D UA-751 semi-automated cuff-oscillometric sphygmomanometer.

M J Jamieson1, J Webster, K Witte, M M Huggins, T M MacDonald, A de Beaux, J C Petrie.   

Abstract

We compared blood pressure recordings made with the A&D UA-751 semi-automated cuff-oscillometric sphygmomanometer (A&D Co. Ltd, Tokyo, Japan) and with a conventional Hawksley random-zero mercury sphygmomanometer (Hawksley and Sons Ltd, Lancing, UK). Simultaneous single-arm recordings were obtained in duplicate with both devices in 200 subjects having blood pressure in the ranges 92-221/51-121 mmHg. The measurements obtained by three observers using the Hawksley sphygmomanometer were compared with recordings from two A&D UA-751 devices. In most cases, there was an acceptable level of agreement between the results, according to the criteria suggested by the Association for the Advancement of Medical Instrumentation (range of differences systolic: mean - 0.9 to 1.4 mmHg, s.d. 4.6-9.8 mmHg; diastolic: mean - 0.6 to 1.3 mmHg, s.d. 2.9-5.1 mmHg), although there were sizeable discrepancies in individual subjects. Thus the A&D UA-751 device appears to be an acceptable alternative to a conventional sphygmomanometer; it should be suitable for routine clinical and limited research use, including intermittent home blood pressure recording.

Entities:  

Mesh:

Year:  1990        PMID: 2160495     DOI: 10.1097/00004872-199004000-00012

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  9 in total

1.  Pressure for change: unresolved issues in blood pressure measurement.

Authors:  M Aylett
Journal:  Br J Gen Pract       Date:  1999-02       Impact factor: 5.386

2.  Evidence for persistence of upper airway narrowing during sleep, 12 years after adenotonsillectomy.

Authors:  C Tasker; J H Crosby; J R Stradling
Journal:  Arch Dis Child       Date:  2002-01       Impact factor: 3.791

3.  Effect of enalapril and quinapril on forearm vascular ACE in man.

Authors:  D Lyons; J Webster; N Benjamin
Journal:  Eur J Clin Pharmacol       Date:  1997       Impact factor: 2.953

4.  Which aspects of breathing during sleep influence the overnight fall of blood pressure in a community population?

Authors:  J R Stradling; C Barbour; J Glennon; B A Langford; J H Crosby
Journal:  Thorax       Date:  2000-05       Impact factor: 9.139

5.  A proposal for scientific validation of instruments for indirect blood pressure measurement at rest, during exercise, and in critical care.

Authors:  Y Iyriboz; C M Hearon
Journal:  J Clin Monit       Date:  1994-05

6.  Angiotensin converting enzyme inhibition does not affect response to exogenous angiotensin II in the forearm of mild-moderate hypertensive patients.

Authors:  D Lyons; J Webster; N Benjamin
Journal:  Eur J Clin Pharmacol       Date:  1994       Impact factor: 2.953

7.  Comparison of agreement between different measures of blood pressure in primary care and daytime ambulatory blood pressure.

Authors:  Paul Little; Jane Barnett; Lucy Barnsley; Jean Marjoram; Alex Fitzgerald-Barron; David Mant
Journal:  BMJ       Date:  2002-08-03

8.  Clinical efficacy of percutaneous renal revascularization with stent placement in hypertension among patients with atherosclerotic renovascular diseases.

Authors:  Seyed Mohammad Hassan Adel; Seyed Masood Syeidian; Mohammad Najafi; Mohammad Nourizadeh
Journal:  J Cardiovasc Dis Res       Date:  2011-01

Review 9.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.