Literature DB >> 21602748

Extracorporeal carbon dioxyde removal for additional pulmonary resection after pneumonectomy.

M Iacovazzi1, N Oreste, P Sardelli, B Barrettara, S Grasso.   

Abstract

Additional pulmonary surgery in a previously pneumonectomized patient requires apnea during surgical manipulation of the surviving lung. We report on a novel approach to manage the intraoperative apnea period, combining apneic oxygenation and minimally invasive, low flow extracorporeal CO2 removal. A 69-year-old man previously submitted to left pneumonectomy was scheduled for wedge resection of a single right upper lobe lesion. During the intraoperative apnea period, oxygenation was maintained through apneic oxygenation with continuous positive airway pressure (CPAP) of 5 cmH2O and inspiratory oxygen fraction (FiO2) of 1 and respiratory acidosis was prevented through extracorporeal CO2 removal, performed with the Decap® system (Hemodec, Salerno, Italy), a veno¬venous pump-driven extracorporeal circuit including a neonatal membrane lung. The extracorporeal circuit was connected to the right femoral vein, accessed via a 14 Fr double lumen catheter. The blood flow through the circuit was 350 mL/min and the sweep flow of oxygen through the membrane lung was 8 L/min. The intraoperative apnea period lasted 13 minutes. Our approach allowed maintaining normocapnia (PaCO2 38,5 and 40 mmHg before and at the end of the apnea period, respectively), preserving oxygenation (P/F ratio 378, 191, 198 and 200 after 3, 6, 9 and 12 min of apnea, respectively). Our report suggests that the minimally invasive CO2 removal associated with apneic oxygenation is an useful technique for managing anesthesiological situations requiring moderate apnea periods.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 21602748

Source DB:  PubMed          Journal:  Minerva Anestesiol        ISSN: 0375-9393            Impact factor:   3.051


  3 in total

Review 1.  Extracorporeal carbon dioxide removal (ECCO2R) in respiratory deficiency and current investigations on its improvement: a review.

Authors:  Hany Hazfiza Manap; Ahmad Khairi Abdul Wahab
Journal:  J Artif Organs       Date:  2016-05-18       Impact factor: 1.731

2.  Low-flow CO₂ removal integrated into a renal-replacement circuit can reduce acidosis and decrease vasopressor requirements.

Authors:  Christian Forster; Jens Schriewer; Stefan John; Kai-Uwe Eckardt; Carsten Willam
Journal:  Crit Care       Date:  2013-07-24       Impact factor: 9.097

3.  Carbon dioxide dialysis in a swine model utilizing systemic and regional anticoagulation.

Authors:  A S Sharma; P W Weerwind; O Bekers; E M Wouters; J G Maessen
Journal:  Intensive Care Med Exp       Date:  2016-01-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.