Literature DB >> 21601136

Real-time passive acoustic monitoring of HIFU-induced tissue damage.

Sacha D Nandlall1, Edward Jackson, Constantin-C Coussios.   

Abstract

Thermal ablation by high-intensity focused ultrasound (HIFU) shows great promise as a noninvasive cancer therapy. This work proposes a novel method of real-time HIFU treatment monitoring that uses the passively monitored acoustic signal emanating from the focus during HIFU exposure. We performed 212 exposures in seven freshly excised ox livers using 1.067-MHz HIFU at a 95% duty cycle for a range of insonation durations and acoustic intensities. Acoustic emissions were recorded using a 15-MHz passive detector aligned confocally and coaxially with the HIFU transducer. Lesion presence and size were ascertained by slicing the tissue in the transverse and axial focal planes post exposure. Our results demonstrate that successful formation of HIFU lesions in ex vivo ox liver is highly correlated with the presence of pronounced dips in the magnitude of the received signal at integer harmonics of the insonation frequency. A detector based on this observation predicted lesioning with >80% accuracy in regimes that were very likely to create lesions (≥60 J of energy) and had an error rate of <6% for exposures that were too short to cause lesioning (≤1 s long). The overall sensitivity and specificity of the detector were 75.6% and 74.2%, respectively. The proposed detector could therefore provide a low-cost means of effectively monitoring clinical HIFU treatments passively and in real time.
Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21601136     DOI: 10.1016/j.ultrasmedbio.2011.02.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  Passive imaging with pulsed ultrasound insonations.

Authors:  Kevin J Haworth; T Douglas Mast; Kirthi Radhakrishnan; Mark T Burgess; Jonathan A Kopechek; Shao-Ling Huang; David D McPherson; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2012-07       Impact factor: 1.840

2.  High-intensity focused ultrasound monitoring using harmonic motion imaging for focused ultrasound (HMIFU) under boiling or slow denaturation conditions.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Iason-Zacharias Apostolakis; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-07       Impact factor: 2.725

3.  Spatial specificity and sensitivity of passive cavitation imaging for monitoring high-intensity focused ultrasound thermal ablation in ex vivo bovine liver.

Authors:  Kevin Haworth; Vasant A Salgaonkar; Nicholas M Corregan; Christy K Holland; T D Mast
Journal:  Proc Meet Acoust       Date:  2013-06-02

4.  Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

5.  Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs.

Authors:  Jin Woo Choi; Jae Young Lee; Eui Jin Hwang; Inpyeong Hwang; Sungmin Woo; Chang Joo Lee; Eun-Joo Park; Byung Ihn Choi
Journal:  Ultrasonography       Date:  2014-03-26

6.  Radio Frequency Ultrasound Time Series Signal Analysis to Evaluate High-intensity Focused Ultrasound Lesion Formation Status in Tissue.

Authors:  Saeedeh Mobasheri; Hamid Behnam; Parisa Rangraz; Jahan Tavakkoli
Journal:  J Med Signals Sens       Date:  2016 Apr-Jun

7.  High-intensity focused ultrasound ablation around the tubing.

Authors:  Jun Yang Siu; Chenhui Liu; Yufeng Zhou
Journal:  PLoS One       Date:  2017-11-21       Impact factor: 3.240

8.  A portable high-intensity focused ultrasound system for the pancreas with 3D electronic steering: a preclinical study in a swine model.

Authors:  Won Chang; Jae Young Lee; Jae Hwan Lee; Jae Seok Bae; Yeon Jin Cho; Kook Jin Kang; Keonho Son; Yul Ri Chung; Kyoung Bun Lee; Joon Koo Han
Journal:  Ultrasonography       Date:  2017-10-13
  8 in total