Literature DB >> 21600836

2D-3D shape reconstruction of the distal femur from stereo X-ray imaging using statistical shape models.

N Baka1, B L Kaptein, M de Bruijne, T van Walsum, J E Giphart, W J Niessen, B P F Lelieveldt.   

Abstract

Three-dimensional patient specific bone models are required in a range of medical applications, such as pre-operative surgery planning and improved guidance during surgery, modeling and simulation, and in vivo bone motion tracking. Shape reconstruction from a small number of X-ray images is desired as it lowers both the acquisition costs and the radiation dose compared to CT. We propose a method for pose estimation and shape reconstruction of 3D bone surfaces from two (or more) calibrated X-ray images using a statistical shape model (SSM). User interaction is limited to manual initialization of the mean shape. The proposed method combines a 3D distance based objective function with automatic edge selection on a Canny edge map. Landmark-edge correspondences are weighted based on the orientation difference of the projected silhouette and the corresponding image edge. The method was evaluated by rigid pose estimation of ground truth shapes as well as 3D shape estimation using a SSM of the whole femur, from stereo cadaver X-rays, in vivo biplane fluoroscopy image-pairs, and an in vivo biplane fluoroscopic sequence. Ground truth shapes for all experiments were available in the form of CT segmentations. Rigid registration of the ground truth shape to the biplane fluoroscopy achieved sub-millimeter accuracy (0.68mm) measured as root mean squared (RMS) point-to-surface (P2S) distance. The non-rigid reconstruction from the biplane fluoroscopy using the SSM also showed promising results (1.68mm RMS P2S). A feasibility study on one fluoroscopic time series illustrates the potential of the method for motion and shape estimation from fluoroscopic sequences with minimal user interaction.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21600836     DOI: 10.1016/j.media.2011.04.001

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  23 in total

Review 1.  Fluoroscopy-based tracking of femoral kinematics with statistical shape models.

Authors:  Marta Valenti; Elena De Momi; Weimin Yu; Giancarlo Ferrigno; Mohsen Akbari Shandiz; Carolyn Anglin; Guoyan Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-09-26       Impact factor: 2.924

2.  Design and validation of automated femoral bone morphology measurements in cerebral palsy.

Authors:  Noyeol Park; Jehee Lee; Ki Hyuk Sung; Moon Seok Park; Seungbum Koo
Journal:  J Digit Imaging       Date:  2014-04       Impact factor: 4.056

3.  Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy.

Authors:  Nora Baka; Bart L Kaptein; J Erik Giphart; Marius Staring; Marleen de Bruijne; Boudewijn P F Lelieveldt; Edward Valstar
Journal:  J Biomech       Date:  2013-10-09       Impact factor: 2.712

4.  A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.

Authors:  Martin G Wagner; Charles R Hatt; David A P Dunkerley; Lindsay E Bodart; Amish N Raval; Michael A Speidel
Journal:  Med Phys       Date:  2018-05-03       Impact factor: 4.071

5.  Prediction of in vivo knee joint kinematics using a combined dual fluoroscopy imaging and statistical shape modeling technique.

Authors:  Jing-Sheng Li; Tsung-Yuan Tsai; Shaobai Wang; Pingyue Li; Young-Min Kwon; Andrew Freiberg; Harry E Rubash; Guoan Li
Journal:  J Biomech Eng       Date:  2014-12       Impact factor: 2.097

6.  Computer-assisted intra-operative verification of surgical outcome for the treatment of syndesmotic injuries through contralateral side comparison.

Authors:  Sarina Thomas; Fabian Isensee; Simon Kohl; Maxim Privalov; Nils Beisemann; Benedict Swartman; Holger Keil; Sven Y Vetter; Jochen Franke; Paul A Grützner; Lena Maier-Hein; Marco Nolden; Klaus Maier-Hein
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-08-07       Impact factor: 2.924

7.  Reconstructing a 3D heart surface with stereo-endoscope by learning eigen-shapes.

Authors:  Bo Yang; Chao Liu; Wenfeng Zheng; Shan Liu; Keli Huang
Journal:  Biomed Opt Express       Date:  2018-11-13       Impact factor: 3.732

8.  Validation of three-dimensional models of the distal femur created from surgical navigation point cloud data for intraoperative and postoperative analysis of total knee arthroplasty.

Authors:  David A J Wilson; Carolyn Anglin; Felix Ambellan; Carl Martin Grewe; Alexander Tack; Hans Lamecker; Michael Dunbar; Stefan Zachow
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-29       Impact factor: 2.924

9.  3D femur model reconstruction from biplane X-ray images: a novel method based on Laplacian surface deformation.

Authors:  Vikas Karade; Bhallamudi Ravi
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07-19       Impact factor: 2.924

10.  Gaussian mixture models based 2D-3D registration of bone shapes for orthopedic surgery planning.

Authors:  Marta Valenti; Giancarlo Ferrigno; Dario Martina; Weimin Yu; Guoyan Zheng; Mohsen Akbari Shandiz; Carolyn Anglin; Elena De Momi
Journal:  Med Biol Eng Comput       Date:  2016-03-23       Impact factor: 2.602

View more