Literature DB >> 21599671

Processing of hematopoietic stem cells from peripheral blood before cryopreservation: use of a closed automated system.

Francesco Zinno1, Fabiola Landi, Maria Cristina Scerpa, Viviana Aureli, Alessandro Lanti, Stefano Ceccarelli, Maurizio Caniglia, Massimino Jan Miele, Nicola Daniele, Attilio Landolfo, Angela Maria Cometa, Franco Locatelli, Giancarlo Isacchi.   

Abstract

BACKGROUND: Hematopoietic stem cell transplantation is commonly used to treat several oncohematologic diseases. The autologous hematopoietic progenitor cells collected through apheresis (HPC-A) must be cryopreserved and stored before use in vivo. Cell processing that precedes cryopreservation of HPC-A includes volume reduction aimed at reducing the amount of dimethyl sulfoxide used, as well as storage space. STUDY DESIGN AND METHODS: The aim of our study was to assess the effectiveness of volume reduction performed with an automated closed system, namely, the Sepax S100 cell separation device (Biosafe SA). A total of 165 procedures were carried out on concentrates collected from 104 adult and pediatric patients. As a control group, 30 HPC-A units processed according to the standard method (i.e., centrifugation at a speed of 850 × g for 10 minutes, followed by manual plasma reduction) were evaluated.
RESULTS: The volume reduction obtained was 59% (range, 20.54%-84.21%; standard deviation [SD], ± 12.19%), going from 236 mL (range, 100-443 mL; SD, ± 80.41 mL) to 97 mL (range, 33.00-263.00 mL; SD, ± 47.41 mL); recovery of nucleated cells was 90% (range, 64.84%-105.93%; SD, ± 8.76%), while that of CD34+ cells was 91% (range, 59.30%-119.37%; SD, ± 13.30%). These values did not differ from those obtained using the standard method. Automated processing required 20 minutes versus 40 minutes of manual processing. DISCUSSION: Our data demonstrate that volume reduction carried out with the Sepax S100 automated system was particularly effective; cell recovery was excellent and the time spent was short. Moreover, the closed system allows cell processing to be carried out in a contamination-controlled environment, in accordance with good manufacturing practice guidelines.
© 2011 American Association of Blood Banks.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21599671     DOI: 10.1111/j.1537-2995.2011.03180.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Validation of an automated procedure to isolate human adipose tissue-derived cells by using the Sepax® technology.

Authors:  Sinan Güven; Marianna Karagianni; Mandy Schwalbe; Simone Schreiner; Jian Farhadi; Sylvain Bula; Karen Bieback; Ivan Martin; Arnaud Scherberich
Journal:  Tissue Eng Part C Methods       Date:  2012-04-02       Impact factor: 3.056

Review 2.  The processing of stem cell concentrates from the bone marrow in ABO-incompatible transplants: how and when.

Authors:  Nicola Daniele; Maria Cristina Scerpa; Cecilia Rossi; Alessandro Lanti; Gaspare Adorno; Giancarlo Isacchi; Francesco Zinno
Journal:  Blood Transfus       Date:  2013-11-21       Impact factor: 3.443

Review 3.  Current translational and clinical practices in hematopoietic cell and gene therapy.

Authors:  David L Digiusto; Hans-Peter Kiem
Journal:  Cytotherapy       Date:  2012-08       Impact factor: 5.414

  3 in total