Literature DB >> 21599293

Tank-treading and tumbling frequencies of capsules and red blood cells.

Alireza Z K Yazdani1, R Murthy Kalluri, Prosenjit Bagchi.   

Abstract

This study is motivated in part by the discrepancy that exists in the literature with regard to the dependence of the tank-treading frequency of red blood cells on the shear rate and suspending medium viscosity. Here we consider three-dimensional numerical simulations of deformable capsules of initially spherical and oblate spheroidal shapes and biconcave discoid representing the red blood cell resting shape. By considering a much broader range of the viscosity ratio (ratio of capsule or cell interior to suspending fluid viscosity), shear rate, and aspect ratio (ratio of minor to major axes) than that considered in the previous experiments, we find several new characteristics of the tank-treading and tumbling frequencies that have not been reported earlier. These new characteristics are the result of the large shape deformation and the coupling between shape and angular oscillations of the capsules or cells. For the spherical and oblate spheroidal capsules, the tank-treading frequency shows a nonmonotonic trend that is characterized by an initial decrease leading to a minimum followed by an increase with increasing viscosity ratio. For red blood cells, we find two regimes of the viscosity dependence of the tank-treading frequency: an exponential regime in which the tank-treading frequency decreases at a slower rate with increasing viscosity ratio, and a logarithmic range in which it decreases at a much faster rate. While this trend agrees well with different theoretical models of shape-preserving capsules, it was not evident in previous experimental results. When the shear rate dependence is considered, the tank-treading frequency of red blood cells and capsules of highly elongated initial shapes exhibits a nonmonotonic trend that is characterized by an initial increase leading to a maximum followed by a sharp decrease with decreasing shear rate. This anomalous behavior of the tank-treading frequency is shown to be due to a breathing-like dynamics of the capsule or cell that is characterized by a repeated emergence and absence of deep, crater-like dimples, and a large swinging motion. We further observe that the tumbling frequency exhibits a decreasing trend with increasing viscosity ratio that is in contrast to the theoretical result for the shape-preserving capsules and is due to the periodic deformation and preferential alignment of the capsules in the extensional quadrant of the flow.

Mesh:

Substances:

Year:  2011        PMID: 21599293     DOI: 10.1103/PhysRevE.83.046305

Source DB:  PubMed          Journal:  Phys Rev E Stat Nonlin Soft Matter Phys        ISSN: 1539-3755


  7 in total

1.  Comment on "Tank-treading and tumbling frequencies of capsules and red blood cells".

Authors:  P Dimitrakopoulos
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2011-11-28

2.  Continuum- and particle-based modeling of shapes and dynamics of red blood cells in health and disease.

Authors:  Xuejin Li; Petia M Vlahovska; George Em Karniadakis
Journal:  Soft Matter       Date:  2013-01-07       Impact factor: 3.679

3.  Full dynamics of a red blood cell in shear flow.

Authors:  Jules Dupire; Marius Socol; Annie Viallat
Journal:  Proc Natl Acad Sci U S A       Date:  2012-12-03       Impact factor: 11.205

4.  Modeling of Biomechanics and Biorheology of Red Blood Cells in Type 2 Diabetes Mellitus.

Authors:  Hung-Yu Chang; Xuejin Li; George Em Karniadakis
Journal:  Biophys J       Date:  2017-07-25       Impact factor: 4.033

5.  Red blood cell shape transitions and dynamics in time-dependent capillary flows.

Authors:  Steffen M Recktenwald; Katharina Graessel; Felix M Maurer; Thomas John; Stephan Gekle; Christian Wagner
Journal:  Biophys J       Date:  2021-12-09       Impact factor: 4.033

6.  Multiplicity of stable orbits for deformable prolate capsules in shear flow.

Authors:  Xiao Zhang; Michael D Graham
Journal:  Phys Rev Fluids       Date:  2020-02-28       Impact factor: 2.537

7.  Image-based model of the spectrin cytoskeleton for red blood cell simulation.

Authors:  Thomas G Fai; Alejandra Leo-Macias; David L Stokes; Charles S Peskin
Journal:  PLoS Comput Biol       Date:  2017-10-09       Impact factor: 4.475

  7 in total