Literature DB >> 21594229

Durability of microtensile bond to nonetched and etched feldspar ceramic: self-adhesive resin cements vs conventional resin.

Rodrigo Othávio Souza1, Anderson A Castilho, Virgílio V Fernandes, Marco Antonio Bottino, Luiz Felipe Valandro.   

Abstract

PURPOSE: The objective of this study was to evaluate the effect of thermocycling (TC), self-adhesive resin cements and surface conditioning on the microtensile bond strength (μTBS) between feldspathic ceramic blocks and resin cements.
MATERIALS AND METHODS: Fifty-six feldspathic ceramic blocks (10 x 7 x 5 mm) (Vita Mark II) were divided into groups according to the factors "resin cement" (3 cements) and "surface conditioning" (no conditioning or conditioning [10% hydrofluoric acid etching for 5 min + silanization]) (n = 8): group 1: conditioning+Variolink II (control group); group 2: no conditioning+Biscem; group 3: no conditioning+RelyX U100; group 4: no conditioning+Maxcem Elite; group 5: conditioning+ Biscem; group 6: conditioning+RelyX U100; group 7: conditioning+Maxcem Elite. The ceramic-cement blocks were sectioned to produce non-trimmed bar specimens (adhered cross-sectional area: 1 ± 0.1 mm2), which were divided into two storage conditions: dry, μTBS immediately after cutting; TC (12,000x, 5°C/55°C). Statistical significance was determined using two-way ANOVA (7 strategies and 2 storage conditions) and the post-hoc Tukey test (p < 0.05).
RESULTS: Resin cement and thermocycling affected the μTBS significantly (p = 0.001). In the dry condition, group 5 (18 ± 6.5 MPa) presented the lowest values of μTBS when compared to the other groups. TC decreased the mean μTBS values significantly (p < 0.05) for all resin cements tested (9.7 ± 2.3 to 22.1 ± 6.3 MPa), except for the resin cement RelyX U100 (22.1 ± 6.3 MPa). In groups 3 and 4, it was not possible to measure μTBS, since these groups had 100% pre-test failures during sectioning. Moreover, the same occurred in group 2 after TC, where 100% failure was observed during thermocycling (spontaneous failures).
CONCLUSION: Hydrofluoric acid etching and silanization of the feldspathic ceramic surface are essential for bonding self-adhesive resin cement to a feldspathic ceramic, regardless of the resin cement used. Non-etched ceramic is not recommended.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21594229     DOI: 10.3290/j.jad.a18784

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  2 in total

1.  Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement.

Authors:  Meltem Bektaş Kömürcüoğlu; Elçin Sağırkaya; Ayça Tulga
Journal:  J Adv Prosthodont       Date:  2017-12-14       Impact factor: 1.904

2.  Bonding values of two contemporary ceramic inlay materials to dentin following simulated aging.

Authors:  Ashraf Abdelfattah Khalil; Khalid Mohamed Abdelaziz
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.