Literature DB >> 21593674

Does the use of a variable stiffness colonoscope offer advantages during colonoscopy under deep sedation? Results of a randomized trial.

Javier Sola-Vera1, Francisco Uceda, Alicia Brotons, Jesús Sáez, Eva Girona, Estefanía Pérez, Maria Dolores Picó, Concepción Grau, Carlos Sillero.   

Abstract

INTRODUCTION: Variable stiffness colonoscope may be useful in performing colonoscopies in nonsedated patients or under endoscopist-controlled sedation. The objective of this study is to evaluate whether this instrument facilitates colonoscopy in patients under deep sedation monitored by an anaesthesiologist.
METHODS: Prospective and randomized study enroling consecutive patients referred for colonoscopy under deep sedation monitored by an anaesthesiologist. In group I, a variable stiffness colonoscope was used, whereas in group II, a standard colonoscope was used. The main variable was the need to change the position of the patient during the endoscopy.
RESULTS: Fifty-six patients were included in group I (variable stiffness colonoscope) and 54 in group II (standard colonoscope). The caecum was reached in 92.9% of patients in group I and in 90.7% of group II (P=0.7). The time required to reach the caecum was significantly less in group I (6.14±3.5 vs. 7.7±3.8; P=0.035). The variable stiffness colonoscope was effective in 66.7% of cases. Changing the position of the patient was necessary in 12.5% of cases in group I compared with 33.3% of cases in group II (P=0.01).
CONCLUSION: The variable stiffness colonoscope avoids the need to change the patient's position and reduces caecal intubation time in patients undergoing colonoscopy under deep sedation controlled by an anaesthesiologist.

Entities:  

Mesh:

Year:  2011        PMID: 21593674     DOI: 10.1097/MEG.0b013e32834793d3

Source DB:  PubMed          Journal:  Eur J Gastroenterol Hepatol        ISSN: 0954-691X            Impact factor:   2.566


  3 in total

1.  Initial experience with a variable width and extreme tip angulation colonoscope.

Authors:  L F Lara; T Erim; A Schneider; N Palekar; B Jimenez; B Murchie; R R Pimentel; R J Charles
Journal:  Tech Coloproctol       Date:  2014-10-18       Impact factor: 3.781

2.  Does the variable-stiffness colonoscope makes colonoscopy easier? A meta-analysis of the efficacy of the variable stiffness colonoscope compared with the standard adult colonoscope.

Authors:  Qin Xie; Bin Chen; Liu Liu; Huatian Gan
Journal:  BMC Gastroenterol       Date:  2012-10-24       Impact factor: 3.067

3.  A randomized controlled trial of comparison on time and rate of cecal and termianl Ileal intubation according to adult-colonoscope length: intermediate versus long.

Authors:  Kwang-Min Kim; Seung-Hwa Lee; Duck-Joo Lee; Kyu-Nam Kim; Sang-Wook Seo; Hyung-Suk Lee; Dong-Ryul Lee
Journal:  J Korean Med Sci       Date:  2013-12-26       Impact factor: 2.153

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.