Literature DB >> 21591927

Quantification of stiffness change in degenerated articular cartilage using optical coherence tomography-based air-jet indentation.

Yan-Ping Huang1, Shu-Zhe Wang, Simo Saarakkala, Yong-Ping Zheng.   

Abstract

Articular cartilage is a thin complex tissue that covers the bony ends of joints. Changes in the composition and structure of articular cartilage will cause degeneration, which may further lead to osteoarthritis. Decreased stiffness is one of the earliest symptoms of cartilage degeneration and also represents the imperfect quality of repaired cartilage. An optical coherence tomography (OCT)-based air-jet indentation system was recently developed in our group to measure the mechanical properties of soft tissues. In this study, this system was applied to quantify the change of mechanical properties of articular cartilage after degeneration induced by enzymatic digestions. Forty osteochondral disks (n = 20 × 2) were prepared from bovine patellae and treated with collagenase and trypsin digestions, respectively. The apparent stiffness of the cartilage was measured by the OCT-based air-jet indentation system before and after the degeneration. The results were also compared with those from a rigid contact mechanical indentation and an ultrasound water-jet indentation. Through the air-jet indentation, it was found that the articular cartilage stiffness dropped significantly by 84% (p < 0.001) and 63% (p < 0.001) on average after collagenase and trypsin digestions, respectively. The stiffness measured by the air-jet indentation system was highly correlated (R > 0.8, p < 0.001) with that from the other two indentation methods. This study demonstrated that the OCT-based air-jet indentation can be a useful tool to quantitatively assess the mechanical properties of articular cartilage, and this encourages us to further develop a miniaturized probe suitable for arthroscopic applications.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21591927     DOI: 10.3109/03008207.2011.555824

Source DB:  PubMed          Journal:  Connect Tissue Res        ISSN: 0300-8207            Impact factor:   3.417


  3 in total

1.  Micro-poromechanics model of fluid-saturated chemically active fibrous media.

Authors:  Anil Misra; Ranganathan Parthasarathy; Viraj Singh; Paulette Spencer
Journal:  Z Angew Math Mech       Date:  2015-02       Impact factor: 1.603

2.  Measuring Human Corneal Stromal Biomechanical Properties Using Tensile Testing Combined With Optical Coherence Tomography.

Authors:  Yi Song; Di Wu; Min Shen; Like Wang; Congzheng Wang; Yong Cai; Chao Xue; George P M Cheng; Yongping Zheng; Yan Wang
Journal:  Front Bioeng Biotechnol       Date:  2022-05-20

Review 3.  Detecting early stage osteoarthritis by optical coherence tomography?

Authors:  Holger Jahr; Nicolai Brill; Sven Nebelung
Journal:  Biomarkers       Date:  2016-02-10       Impact factor: 2.658

  3 in total