Literature DB >> 21591672

Demonstration of combined zero-valent iron and electrical resistance heating for in situ trichloroethene remediation.

M J Truex1, T W Macbeth, V R Vermeul, B G Fritz, D P Mendoza, R D Mackley, T W Wietsma, G Sandberg, T Powell, J Powers, E Pitre, M Michalsen, S J Ballock-Dixon, L Zhong, M Oostrom.   

Abstract

The effectiveness of in situ treatment using zero-valent iron (ZVI) for nonaqueous phase or significant sediment-associated contaminant mass can be limited by relatively low rates of mass transfer to bring contaminants in contact with the reactive media. For a field test in a trichloroethene (TCE) source area, combining moderate-temperature subsurface electrical resistance heating with in situ ZVI treatment was shown to accelerate TCE treatment by a factor of about 4 based on organic daughter products and a factor about 8 based on chloride concentrations. A mass-discharge-based analysis was used to evaluate reaction, dissolution, and volatilization processes at ambient groundwater temperature (~10 °C) and as temperature was increased up to about 50 °C. Increased reaction and contaminant dissolution were observed with increased temperature, but vapor- or aqueous-phase migration of TCE out of the treatment zone was minimal during the test because reactions maintained low aqueous-phase TCE concentrations.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21591672     DOI: 10.1021/es104266a

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  1 in total

1.  Nanoscale Metallic Iron for Environmental Remediation: Prospects and Limitations.

Authors:  Chicgoua Noubactep; Sabine Caré; Richard Crane
Journal:  Water Air Soil Pollut       Date:  2011-09-22       Impact factor: 2.520