T D Wohlsen1. 1. Unitywater, Maroochydore Sewage Treatment Plant, Maroochydore, Queensland, Australia. tracey.wohlsen@unitywater.com
Abstract
AIMS: The equivalence of Oxoid (CM 1046) Brilliance((TM)) E. coli/coliform selective agar to mFC agar, as used in the Australian/New Zealand Standard Method to detect thermotolerant coliforms and Escherichia coli in water samples, was assessed. METHODS AND RESULTS: A total of 244 water samples were analysed in parallel over a 5-month period. Sewage effluent samples (n = 131, sites = 43), freshwater (n = 62, sites = 18) and marine/brackish water samples (n = 51, sites = 23) were analysed. The Wilcoxon matched-pairs signed-ranks test showed a varying degree of statistical difference between the two methods. All matrices had a higher recovery in the trial method. Enterococci faecalis, Aeromonas spp. and Vibrio spp. did not grow on the CM1046 agar, and Pseudomonas aeruginosa and Enterobacter aerogenes were inhibited. CONCLUSIONS: The use of CM 1046 for the detection and enumeration of E. coli and thermotolerant coliforms in water samples is a suitable alternative to the AS/NZS Standard Method. SIGNIFICANCE AND IMPACT OF THE STUDY: The use of CM1046 agar was less labour intensive and time consuming, as no secondary confirmation steps were required. Confirmed results could be reported within 24 h of sample analysis, as compared to 48 h with the reference method. Public health concerns can be addressed in a more efficient manner.
AIMS: The equivalence of Oxoid (CM 1046) Brilliance((TM)) E. coli/coliform selective agar to mFC agar, as used in the Australian/New Zealand Standard Method to detect thermotolerant coliforms and Escherichia coli in water samples, was assessed. METHODS AND RESULTS: A total of 244 water samples were analysed in parallel over a 5-month period. Sewage effluent samples (n = 131, sites = 43), freshwater (n = 62, sites = 18) and marine/brackish water samples (n = 51, sites = 23) were analysed. The Wilcoxon matched-pairs signed-ranks test showed a varying degree of statistical difference between the two methods. All matrices had a higher recovery in the trial method. Enterococci faecalis, Aeromonas spp. and Vibrio spp. did not grow on the CM1046 agar, and Pseudomonas aeruginosa and Enterobacter aerogenes were inhibited. CONCLUSIONS: The use of CM 1046 for the detection and enumeration of E. coli and thermotolerant coliforms in water samples is a suitable alternative to the AS/NZS Standard Method. SIGNIFICANCE AND IMPACT OF THE STUDY: The use of CM1046 agar was less labour intensive and time consuming, as no secondary confirmation steps were required. Confirmed results could be reported within 24 h of sample analysis, as compared to 48 h with the reference method. Public health concerns can be addressed in a more efficient manner.
Authors: Katarzyna Glińska-Lewczuk; Iwona Gołaś; Józef Koc; Anna Gotkowska-Płachta; Monika Harnisz; Andrzej Rochwerger Journal: Environ Monit Assess Date: 2016-10-18 Impact factor: 2.513