Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays.

Jing Zhang Ji1, Qing H Meng.   

Abstract

BACKGROUND: Pre-analytical error accounts for major total laboratory errors. We assessed the impacts of hemolysis, icterus, and lipemia on laboratory tests on Roche Cobas 6000.
METHODS: Various concentrations of hemoglobin, bilirubin, or Intralipid® were added into the plasma to simulate hemolytic, icteric, or lipemic samples. The analytes were then measured on Roche Cobas 6000 and the change of the analyte concentrations was determined.
RESULTS: For most of the chemistry assays, our data were in a good agreement with Roche package inserts. However some assays had significant interference at lower index values while others were affected at higher index than the Roche package inserts indicated. In addition, we observed the positive interference by hemolysis on ALT, lipase, total protein, potassium, and iron. Negative interference was noted on calcium and CK. Most of the immunoassays were not affected by hemoglobin, bilirubin, and lipids although there were a few exceptions. Several therapeutic drugs were affected either positively or negatively by hemolysis, icterus, or lipemia to a certain extent.
CONCLUSIONS: We have demonstrated some test interferences which have not been reported previously on the Cobas 6000. The implementation of the cut-off indices on Cobas 6000 would provide more accurate test result reporting.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21575617     DOI: 10.1016/j.cca.2011.04.034

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  20 in total

1.  Icteric human samples: Icterus index and method of estimating an interference-free value for 16 biochemical analyses.

Authors:  Alain Nicolay; Anne-Marie Lorec; Guy Gomez; Henri Portugal
Journal:  J Clin Lab Anal       Date:  2017-04-11       Impact factor: 2.352

2.  Quantitative Detection of Nucleoside Analogues by Multi-enzyme Biosensors using Time-Resolved Kinetic Measurements.

Authors:  Pravin Muthu; Stefan Lutz
Journal:  ChemMedChem       Date:  2016-03-02       Impact factor: 3.466

3.  Markers of iron metabolism in retired racing Greyhounds with and without osteosarcoma.

Authors:  J T Caro; L M Marín; M C Iazbik; S Zaldivar-López; H Borghese; C G Couto
Journal:  Vet Clin Pathol       Date:  2013-09       Impact factor: 1.180

4.  Mechanism of scrapie prion precipitation with phosphotungstate anions.

Authors:  Dana J Levine; Jan Stöhr; Lillian E Falese; Julian Ollesch; Holger Wille; Stanley B Prusiner; Jeffrey R Long
Journal:  ACS Chem Biol       Date:  2015-02-19       Impact factor: 5.100

5.  Effects of pre-analytical processes on blood samples used in metabolomics studies.

Authors:  Peiyuan Yin; Rainer Lehmann; Guowang Xu
Journal:  Anal Bioanal Chem       Date:  2015-03-04       Impact factor: 4.142

6.  It takes acid, rather than ice, to freeze glucose.

Authors:  S A A van den Berg; M H M Thelen; L P W Salden; S W van Thiel; K J M Boonen
Journal:  Sci Rep       Date:  2015-03-09       Impact factor: 4.379

7.  Development of an integrated reporting system for verifying hemolysis, icterus, and lipemia in clinical chemistry results.

Authors:  Dong Hoon Shin; Juwon Kim; Young Uh; Se Il Lee; Dong Min Seo; Kab Seung Kim; Jae Yun Jang; Man Hee Lee; Kwang Ro Yoon; Kap Jun Yoon
Journal:  Ann Lab Med       Date:  2014-06-19       Impact factor: 3.464

Review 8.  Lipemia: causes, interference mechanisms, detection and management.

Authors:  Nora Nikolac
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

9.  Frequency and causes of lipemia interference of clinical chemistry laboratory tests.

Authors:  Sandhya Mainali; Scott R Davis; Matthew D Krasowski
Journal:  Pract Lab Med       Date:  2017-02-03

10.  Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory.

Authors:  Neha Dhungana; Cory Morris; Matthew D Krasowski
Journal:  Pract Lab Med       Date:  2017-05-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.