| Literature DB >> 21573091 |
Bryndon B Hatch1, Majid Moshirfar, Andrew J Ollerton, Shameema Sikder, Mark D Mifflin.
Abstract
PURPOSE: To compare differences in visual acuity, contrast sensitivity, complications, and higher-order ocular aberrations (HOAs) in eyes with stable myopia undergoing either photo-refractive keratectomy (PRK) or thin-flap laser in situ keratomileusis (LASIK) (intended flap thickness of 90 μm) using the VISX Star S4 CustomVue excimer laser and the IntraLase FS60 femtosecond laser at 1, 3, and 6 months postoperatively.Entities:
Keywords: photorefractive keratectomy; thin-flap LASIK; visual function
Year: 2011 PMID: 21573091 PMCID: PMC3090298 DOI: 10.2147/OPTH.S18967
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Preoperative group comparisons
| Mean UDVA (logMAR) ± SD | 1.286 ± 0.312 | 1.269 ± 1.178 | 0.866 |
| Mean UDVA (20/x) ± SD | 478.26 ± 283.10 | 480.65 ± 301.20 | 0.855 |
| CDVA (logMAR) ± SD | −0.0211 ± 0.0564 (−0.125 to 0.097) | −0.0211 ± 0.0564 (−0.125 to 0.097) | 1.00 |
| CDVA (20/x) ± SD | 19.2 ± 2.4 (15 to 25) | 19.2 ± 2.4 (15 to 25) | 1.00 |
| Sphere (D) ± SD | −4.67 ± 1.95 (−8.50 to −1.50) | −4.74 ± 2.07 (−7.75 to −0.60) | 0.732 |
| Cylinder (D) ± SD | 0.86 ± 0.72 (0.00 to 2.25) | 0.81 ± 0.70 (0.00 to 2.50) | 0.805 |
| Central corneal thickness (μm) ± SD | 556 ± 29 (502 to 596) | 554 ± 27 (503 to 598) | 0.719 |
Notes: Values represented as mean ± standard deviation (range);
Independent samples t-test.
Abbreviations: UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity.
Visual acuity comparisons
| UDVA (logMAR) | 0.082 ± 0.111 | −0.012 ± 0.099 | 0.003 | −0.053 ± 0.070 | −0.046 ± 0.091 | 0.753 | −0.043 ± 0.668 | −0.061 ± 0.099 | 0.466 |
| UDVA (20/x) | 25 ± 7.36 | 20 ± 5.32 | 0.009 | 18 ± 2.89 | 18.4 ± 4.26 | 0.699 | 18.33 ± 2.82 | 17.83 ± 4.22 | 0.629 |
| SE (D) | 0.125 ± 0.978 (−3.625 to 1.165) | 0.236 ± 0.826 (−2.95 to 1.645) | 0.669 | 0.221 ± 0.532 (−1.065 to 1.215) | −0.045 ± 0.338 (−0.625 to 0.625) | 0.803 | 0.113 ± 0.557 (−0.870 to 1.450) | 0.049 ± 0.310 − (−0.500 to 0.750) | 0.277 |
| Sphere (D) | −0.340 ± 0.444 (−1.250 to 0.750) | −0.200 ± 0.280 (−0.750 to 0.000) | 0.189 | −0.180 ± 0.265 (−0.750 to 0.250) | −0.140 ± 0.315 (−0.750 to 0.500) | 0.630 | −0.229 ± 0.329 (−0.750 to 0.750) | −0.087 ± 0.288 − (−0.750 to 0.500) | 0.123 |
| Cylinder (D) | 0.590 ± 0.338 (0.000 to 1.250) | 0.290 ± 0.280 (0.000 to 1.000) | 0.001 | 0.190 ± 0.263 (0.000 to 0.750) | 0.190 ± 0.231 (0.000 to 0.750) | 1.00 | 0.304 ± 0.238 (0.000 to 0.750) | 0.298 ± 0.288 (0.000 to 1.000) | 0.932 |
Notes: Values represented as mean ± standard deviation (range);
Independent samples t-test.
Abbreviations: UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity.
Efficacy, predictability, and safety comparisons of PRK and thin-flap LASIK
| 0.009 | 0.699 | 0.718 | |||||||
| 20/15 or better | 1 (4) | 7 (29) | 11 (44) | 12 (48) | 9 (38) | 13 (54) | |||
| 20/20 or better | 11 (44) | 21 (84) | 24 (96) | 23 (92) | 24 (96) | 23 (92) | |||
| 20/25 or better | 19 (76) | 24 (98) | 25 (100) | 23 (92) | 25 (100) | 24 (96) | |||
| 20/30 or better | 23 (92) | 24 (98) | 25 (100) | 25 (100) | |||||
| 20/40 or better | 24 (96) | 25 (100) | |||||||
| 20/50 or better | 25 (100) | ||||||||
| 0.189 | 0.630 | 0.242 | |||||||
| ±0.50 D of emmetropia | 19 (76) | 23 (92) | 24 (96) | 23 (92) | 23 (92) | 22 (88) | |||
| ±1.00 D of emmetropia | 5 (20) | 2 (8) | 1 (4) | 2 (8) | 2 (8) | 3 (12) | |||
| ±1.50 D of emmetropia | 1 (4) | ||||||||
| 0.011 | 0.578 | 0.462 | |||||||
| Loss of 2 lines | 2 (8) | 0 (0) | 0 (0) | 0 (0) | 0 (0) | 0 (0) | |||
| Loss of 1 line | 4 (16) | 2 (9) | 2 (8) | 1 (4) | 0 (0) | 0 (0) | |||
| No loss of lines | 16 (64) | 14 (56) | 11 (44) | 13 (52) | 9 (36) | 11 (44) | |||
| Gain of 1 line | 3 (12) | 9 (39) | 11 (42) | 10 (40) | 15 (60) | 13 (52) | |||
| Gain of 2 lines or more | 0 (0) | 0 (0) | 1 (4) | 1 (4) | 1 (4) | 1 (4) | |||
Notes: Values represented as mean ± standard deviation (range);
Independent samples t-test.
Abbreviations: UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity.
Figure 1Comparison of contrast sensitivity measured at 3, 6, 12, and 18 cycles per degree (cpd) preoperatively and at postoperative 1, 3, and 6 months using the Vectorvision CSV-1000E chart (n = 25 for each group, P ≥ 0.156).
Figure 2Comparison of ocular higher-order aberrations before surgery and at postoperative 1, 3, and 6 months. Coma, Z(3,1), trefoil, Z(3,3), and spherical aberration, Z(4,0), were measured using the WaveScan at a mean diameter of 6 mm (n = 5 for each group, P ≥ 0.101).