Literature DB >> 21571739

External radiation exposure of personnel in nuclear medicine from 18F, 99mTC and 131I with special reference to fingers, eyes and thyroid.

S Leide-Svegborn1.   

Abstract

The radiation exposure of fingers, thyroid and eyes of workers handling radiopharmaceuticals during various nuclear medicine procedures was measured using thermoluminescent dosemeters. Dosemeters were placed on the finger tips of 19 workers on several different occasions for various procedures. Additionally, the routinely determined whole-body doses to various groups of workers were analysed. The finger dose measurements demonstrated clear differences between the various tasks, from 0.0012 µGy MBq(-1) (unpacking and installing (99)Mo/(99m)Tc-generator) to 3.0 µGy MBq(-1) (syringe withdrawal, injection and waste handling of (18)F-FDG). As long as the worker was handling (99m)Tc, the dose to the fingers was well below the ICRP dose limits, even when the activity was high. Special concern should, however, be devoted to the handling of (18)F, since the dose to the fingers could easily reach the dose limits. The estimated dose to eyes and thyroid was well below the dose limits. Since the introduction of the positron emission tomography/computed tomography facility, the annual whole-body dose has increased for those directly involved in the handling of (18)F. The annual whole-body dose of 0.2-2.5 mGy was, however, well below the dose limits.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21571739     DOI: 10.1093/rpd/ncr213

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Exposure Doses to Technologists Working in 7 PET/CT Departments.

Authors:  Weiguo Li; Lianying Fang; Jieqing Li
Journal:  Dose Response       Date:  2020-07-09       Impact factor: 2.658

2.  Cataract Risk in a Cohort of U.S. Radiologic Technologists Performing Nuclear Medicine Procedures.

Authors:  Marie-Odile Bernier; Neige Journy; Daphnee Villoing; Michele M Doody; Bruce H Alexander; Martha S Linet; Cari M Kitahara
Journal:  Radiology       Date:  2017-10-11       Impact factor: 11.105

3.  Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry.

Authors:  S Zargan; P Ghafarian; A Shabestani Monfared; A A Sharafi; M Bakhshayeshkaram; M R Ay
Journal:  J Biomed Phys Eng       Date:  2017-03-01

4.  ESTIMATION OF HP(3) AMONG STAFF MEMBERS IN TWO NUCLEAR MEDICINE UNITS IN FINLAND.

Authors:  C Lindholm; A Pekkarinen; O Sipilä; A-L Manninen; M Lehtinen; T Siiskonen
Journal:  Radiat Prot Dosimetry       Date:  2020-08-28       Impact factor: 0.972

5.  Using Monte Carlo methods for Hp(0.07) values assessment during the handling of 18F-FDG.

Authors:  Łukasz Albiniak; Małgorzata Wrzesień
Journal:  Radiat Environ Biophys       Date:  2020-07-29       Impact factor: 1.925

  5 in total