Literature DB >> 21571673

Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics.

Ranjay Chakraborty1, Scott A Read, Michael J Collins.   

Abstract

PURPOSE: To investigate the pattern of diurnal variations in axial length (AL), choroidal thickness, intraocular pressure (IOP), and ocular biometrics over 2 consecutive days.
METHODS: Measurements of ocular biometrics and IOP were collected for 30 young adult subjects (15 myopes, 15 emmetropes) at 10 different times over 2 consecutive days. Five sets of measurements were collected each day at approximately 3-hour intervals, with the first measurement taken at ~9 AM and final measurement at ~9 PM.
RESULTS: AL underwent significant diurnal variation (P < 0.0001) that was consistently observed across the 2 measurement days. The longest AL was typically observed at the second measurement session (mean time, 12:26) and the shortest AL at the final session of each day (mean time, 21:06). The mean diurnal change in AL was 0.032 ± 0.018 mm. Choroidal thickness underwent significant diurnal variation (mean change, 0.029 ± 0.016 mm; P < 0.001) and varied approximately in antiphase to the AL changes. Significant diurnal variations were also found in vitreous chamber depth (VCD; mean change, 0.06 ± 0.029 mm; P < 0.0001) and IOP (mean change, 3.54 ± 0.84 mm Hg; P < 0.0001). A positive association was found between the variations of AL and IOP (r(2) = 0.17, P < 0.0001) and AL and VCD (r(2) = 0.31, P < 0.0001) and a negative association between AL and choroidal thickness (r(2) = 0.13, P < 0.0001). There were no significant differences in the magnitude and timing of diurnal variations associated with refractive error.
CONCLUSIONS: Significant diurnal variations in AL, choroidal thickness, and IOP were consistently observed over 2 consecutive days of testing.

Entities:  

Mesh:

Year:  2011        PMID: 21571673     DOI: 10.1167/iovs.11-7364

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  127 in total

1.  Correlation between serum level of vascular endothelial growth factor and subfoveal choroidal thickness in patients with POEMS syndrome.

Authors:  Hirotaka Yokouchi; Takayuki Baba; Sonoko Misawa; Setsu Sawai; Minako Beppu; Masayasu Kitahashi; Toshiyuki Oshitari; Satoshi Kuwabara; Shuichi Yamamoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-11-04       Impact factor: 3.117

2.  [Is choroidal thickness of importance in idiopathic macular hole?].

Authors:  K B Schaal; S Pollithy; S Dithmar
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

3.  Comparison of choroidal thickness measured by two methods.

Authors:  Wei Chen; Zhi-Tao Wang; Hong Zhang
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

4.  Diurnal intraocular pressure fluctuation and its risk factors in angle-closure and open-angle glaucoma.

Authors:  S Srinivasan; N S Choudhari; M Baskaran; R J George; B Shantha; L Vijaya
Journal:  Eye (Lond)       Date:  2015-11-13       Impact factor: 3.775

5.  Choroidal thickness change following vitrectomy in idiopathic epiretinal membrane and macular hole.

Authors:  Seong Joon Ahn; Se Joon Woo; Kyu Hyung Park
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-09-04       Impact factor: 3.117

6.  Diurnal variations of central corneal thickness and intraocular pressure in dogs from 8:00 am to 8:00 pm.

Authors:  Eva Martín-Suárez; Carolina Molleda; Rodrigo Tardón; Alba Galán; José Gallardo; José Molleda
Journal:  Can Vet J       Date:  2014-04       Impact factor: 1.008

7.  Ocular changes in TgF344-AD rat model of Alzheimer's disease.

Authors:  Yuchun Tsai; Bin Lu; Alexander V Ljubimov; Sergey Girman; Fred N Ross-Cisneros; Alfredo A Sadun; Clive N Svendsen; Robert M Cohen; Shaomei Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-01-29       Impact factor: 4.799

8.  Changes in choroidal thickness, axial length, and ocular perfusion pressure accompanying successful glaucoma filtration surgery.

Authors:  N Kara; O Baz; C Altan; B Satana; T Kurt; A Demirok
Journal:  Eye (Lond)       Date:  2013-06-07       Impact factor: 3.775

9.  [Are there diurnal variations in choroidal thickness?].

Authors:  S Pollithy; A Höh; B Dobner; G U Auffarth; S Dithmar
Journal:  Ophthalmologe       Date:  2015-08       Impact factor: 1.059

10.  Validation of Macular Choroidal Thickness Measurements from Automated SD-OCT Image Segmentation.

Authors:  Michael D Twa; Krystal L Schulle; Stephanie J Chiu; Sina Farsiu; David A Berntsen
Journal:  Optom Vis Sci       Date:  2016-11       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.