Literature DB >> 21571604

Biocompatibility of chronically implanted transverse intrafascicular multichannel electrode (TIME) in the rat sciatic nerve.

Jordi Badia, Tim Boretius, Arán Pascual-Font, Esther Udina, Thomas Stieglitz, Xavier Navarro.   

Abstract

The transverse intrafascicular multichannel electrode (TIME) is intended to be transversally implanted in the peripheral nerve and to selectively interface subsets of axons in different fascicles within the same nerve. Two versions of TIME (TIME-2, TIME-3) were designed and tested for biocompatibility and safety in the sciatic nerve of the rat. TIME-2 was implanted in two groups: one group had only an acute implant and the second group had chronic implantation for 2 months; a third group was also chronically implanted with the TIME-3 version, designed to avoid the mechanical traction produced by muscles motion. We evaluated the functional and morphological effects of either TIME-2 or TIME-3 implanted in the rat sciatic nerve for 2 months. The results of the study indicate that implantation of the TIME-2 and TIME-3 devices in the rat sciatic nerve did not cause significant axonal loss or demyelination, as evidenced by the functional and histological results. The results of this study indicate that the TIME-2 and TIME-3 designs are biocompatible and safe after chronic implantation in a small peripheral nerve, such as the rat sciatic nerve.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21571604     DOI: 10.1109/TBME.2011.2153850

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  16 in total

1.  Determination of electrode to nerve fiber distance and nerve conduction velocity through spectral analysis of the extracellular action potentials recorded from earthworm giant fibers.

Authors:  Shaoyu Qiao; Onyekachi Odoemene; Ken Yoshida
Journal:  Med Biol Eng Comput       Date:  2012-06-20       Impact factor: 2.602

2.  Delaying discharge after the stimulus significantly decreases muscle activation thresholds with small impact on the selectivity: an in vivo study using TIME.

Authors:  Paweł Maciejasz; Jordi Badia; Tim Boretius; David Andreu; Thomas Stieglitz; Winnie Jensen; Xavier Navarro; David Guiraud
Journal:  Med Biol Eng Comput       Date:  2015-02-06       Impact factor: 2.602

3.  Spatio-temporal feature extraction in sensory electroneurographic signals.

Authors:  C Silveira; R N Khushaba; E Brunton; K Nazarpour
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2022-06-06       Impact factor: 4.019

4.  A system and method to interface with multiple groups of axons in several fascicles of peripheral nerves.

Authors:  Anil K Thota; Sathyakumar Kuntaegowdanahalli; Amy K Starosciak; James J Abbas; Jorge Orbay; Kenneth W Horch; Ranu Jung
Journal:  J Neurosci Methods       Date:  2014-08-01       Impact factor: 2.390

Review 5.  Bionic intrafascicular interfaces for recording and stimulating peripheral nerve fibers.

Authors:  Ranu Jung; James J Abbas; Sathyakumar Kuntaegowdanahalli; Anil K Thota
Journal:  Bioelectron Med (Lond)       Date:  2017-12-14

6.  Fabrication and modeling of recessed traces for silicon-based neural microelectrodes.

Authors:  Nicholas F Nolta; Pejman Ghelich; Alpaslan Ersöz; Martin Han
Journal:  J Neural Eng       Date:  2020-10-08       Impact factor: 5.379

7.  Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation.

Authors:  Stephen M Restaino; Erkinay Abliz; Kelliann Wachrathit; Victor Krauthamer; Sameer B Shah
Journal:  J Neuroeng Rehabil       Date:  2014-04-23       Impact factor: 4.262

Review 8.  Invasive Intraneural Interfaces: Foreign Body Reaction Issues.

Authors:  Fiorenza Lotti; Federico Ranieri; Gianluca Vadalà; Loredana Zollo; Giovanni Di Pino
Journal:  Front Neurosci       Date:  2017-09-06       Impact factor: 4.677

Review 9.  Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.

Authors:  Usman Ghafoor; Sohee Kim; Keum-Shik Hong
Journal:  Front Neurorobot       Date:  2017-10-31       Impact factor: 2.650

10.  Fascicular Topography of the Human Median Nerve for Neuroprosthetic Surgery.

Authors:  Ignacio Delgado-Martínez; Jordi Badia; Arán Pascual-Font; Alfonso Rodríguez-Baeza; Xavier Navarro
Journal:  Front Neurosci       Date:  2016-07-01       Impact factor: 4.677

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.