Removal of locked volar plates after distal radius fractures.

Cassie Gyuricza1, Michelle Gerwin Carlson, Andrew J Weiland, Scott W Wolfe, Robert N Hotchkiss, Aaron Daluiski.   

Abstract

PURPOSE: We present our experience with removal of locked volar distal radius plates and screws and note the indications for removal, types of plates removed, completeness of hardware removal, and complications occurring during plate removal.
METHODS: We reviewed all distal radial volar locking plates removed at our institution from 2004 to 2009. A total of 28 patients operated on by 5 hand surgeons were identified. We gathered information regarding the incidence of successful removal of hardware and operative findings in cases of difficult removal of hardware.
RESULTS: A total of 28 patients (16 women, 12 men) underwent removal of locked volar distal radius plates from 2004 to 2009. The mean length of implantation was 63 weeks (range, 3-223 wk). Reasons for removal of hardware included tenosynovitis, tendon rupture, pain, and prominent or intra-articular hardware. Of 28 cases of locked volar plate removal, 2 had complications. In the first case, a screw was cross-threaded in an earlier generation DVR Hand Innovations plate implanted in 2003. The plate and screw were removed by rotating them out as 1 unit. In the second case, in which the current generation DVR Hand Innovations plate was implanted in 2007, the recess in the screw head had been stripped on insertion. The plate was cut and the remaining fragment of plate and screw were removed together. Despite these difficulties, hardware was successfully removed completely in 28 patients.
CONCLUSIONS: This case series highlights the result that all removals of locked volar plates were successful. There were 2 complications, and strategies for removal are described. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21571444     DOI: 10.1016/j.jhsa.2011.03.032

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  10 in total

1.  The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.

Authors:  Lindley B Wall; Michael D Brodt; Matthew J Silva; Martin I Boyer; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2012-02-02       Impact factor: 2.230

2.  Improving accuracy and confidence in distal radius volar plate screw placement through supplemental radiography: examining specialty, education, and experience levels.

Authors:  Archit Patel; Maya Deza Culbertson; Philip Lahey; Michael Semenovski; Jack Choueka
Journal:  Hand (N Y)       Date:  2013-09

3.  Re-fracture of Distal Radius and Hardware Repair in the Setting of Trauma.

Authors:  Brandon P Lucke-Wold; Patrick C Bonasso; Glen Jacob
Journal:  Med Student Res J       Date:  2017

4.  Magnesium Bioabsorbable Screw Fixation of Radial Styloid Fractures: Case Report.

Authors:  Adil Turan; Yusuf Alper Kati; Baver Acar; Ozkan Kose
Journal:  J Wrist Surg       Date:  2019-04-22

5.  Indications for implant removal after fracture healing: a review of the literature.

Authors:  D I Vos; M H J Verhofstad
Journal:  Eur J Trauma Emerg Surg       Date:  2013-04-12       Impact factor: 3.693

6.  Volar locking plate removal after distal radius fracture: a 10-year retrospective study.

Authors:  Jun-Ku Lee; Younghun Lee; Choongki Kim; Minwook Kim; Soo-Hong Han
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-29       Impact factor: 3.067

7.  Relationship between plate removal and Soong grading following surgery for fractured distal radius.

Authors:  Caroline A Selles; Sam T H Reerds; Gert Roukema; Kees H van der Vlies; Berry I Cleffken; Niels W L Schep
Journal:  J Hand Surg Eur Vol       Date:  2017-08-21

8.  Volar Locking Plate Fixation for Distal Radius Fractures by Intraoperative Computed Tomographic-Guided Navigation.

Authors:  Akira Kawabata; Yusuke Sogabe; Yukiko Morimoto; Kiyohito Takamatsu
Journal:  J Hand Surg Glob Online       Date:  2020-09-08

9.  Incidence for volar locking plate removal following distal radius fracture surgery.

Authors:  Vili Palola; Ville Ponkilainen; Tuomas Huttunen; Antti Launonen; Ville M Mattila
Journal:  Arch Orthop Trauma Surg       Date:  2020-08-30       Impact factor: 3.067

10.  Improvement in Functional Outcomes After Elective Symptomatic Orthopaedic Implant Removal.

Authors:  Benjamin R Williams; Dylan L McCreary; Harsh R Parikh; Melissa S Albersheim; Brian P Cunningham
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.