Literature DB >> 21570687

An analysis of the measurement principle of smart brackets for 3D force and moment monitoring in orthodontics.

S Rues1, B Panchaphongsaphak, P Gieschke, O Paul, B G Lapatki.   

Abstract

Measuring the three-dimensional (3D) force-moment (F/M) systems applied for correcting tooth malposition is highly desirable for accurate spatial control of tooth movement and for reducing traumatic side effects such as irreversible root resorption. To date, suitable tools for monitoring the applied F/M system during therapy are lacking. We have previously introduced a true-scale orthodontic bracket with an integrated microelectronic stress sensor system for 3D F/M measurements on individual teeth with a perspective for clinical application. The underlying theoretical concept assumes a linear correlation between externally applied F/M systems and mechanical stresses induced within the smart bracket. However, in combined applications of F/M components the actual wire-bracket contacts may differ from those caused by separate applications of corresponding individual F/M components, thus violating the principle of linear superposition of mechanical stresses. This study systematically evaluates this aspect using finite element (FE) simulations and measurements with a real smart bracket. The FE analysis indicated that variability in the wire-bracket contacts is a major source for measurement errors. By taking the critical F/M combinations into account in the calibration of the real smart bracket, we were able to reduce the mean measurement error in five of the six F/M components to values <0.12 N and <0.04 N cm. Bucco-lingually directed forces still showed mean errors up to 0.21 N. Improving the force measurement accuracy and integrating components for telemetric energy and data transfer are the next steps towards clinical application of intelligent orthodontic appliances based on smart brackets.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21570687     DOI: 10.1016/j.jbiomech.2011.04.029

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Locating the center of resistance in individual teeth via two- and three-dimensional radiographic data.

Authors:  M E Geiger; B G Lapatki
Journal:  J Orofac Orthop       Date:  2014-03-02       Impact factor: 1.938

2.  Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor.

Authors:  Xiaowei Li; Chaochao Ren; Zheyao Wang; Pai Zhao; Hongmei Wang; Yuxing Bai
Journal:  Korean J Orthod       Date:  2016-03-18       Impact factor: 1.372

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.