Literature DB >> 21570557

Comparison of uterine artery blood flow with levonorgestrel intrauterine system and copper intrauterine device.

Berna Haliloglu1, Aygen Celik, Erdin Ilter, Serpil Bozkurt, Umit Ozekici.   

Abstract

BACKGROUND: As a contraceptive method, we investigated whether the levonorgestrel-releasing intrauterine system (LNG-IUS) has any effect on uterine artery blood flow when compared with copper intrauterine device (IUD). STUDY
DESIGN: Sixty women with copper IUD and 60 women with LNG-IUS were included in the study. The age, gravidity, parity, body mass index (BMI) and menstrual flow pattern using a pictorial chart were recorded. All women were assessed by ultrasonography at the preinsertion period and 1 year after insertion. The pulsatility and resistance indices (PI and RI, respectively) of the uterine artery and endometrial thickness were evaluated in the preinsertion and postinsertion periods.
RESULTS: In copper IUD users, preinsertion and postinsertion ultrasonographic assessments were not significantly different. However, postinsertion RI was significantly higher compared with preinsertion RI in LNG-IUS users (p=.001). The PI was also increased 1 year after insertion, but it did not reach statistically significant levels (p=.08). Endometrial thickness was also significantly decreased in the postinsertion period in women with LNG-IUS (p=.04).
CONCLUSION: The significant increase in uterine artery RI in LNG-IUS users 1 year after insertion might be due to its local progestational effects. It might also indicate the mechanism of the LNG-IUS in reducing menstrual blood flow.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21570557     DOI: 10.1016/j.contraception.2010.09.001

Source DB:  PubMed          Journal:  Contraception        ISSN: 0010-7824            Impact factor:   3.375


  3 in total

1.  Morphological and Ultrastructural Changes in Human Endometrium Following Low-Dose Levonorgestrel Contraceptive Intrauterine Systems (LNG-IUS-12) 13.5 mg.

Authors:  Minghan Chai; Shili Su; Baihua Dong
Journal:  J Obstet Gynaecol India       Date:  2014-10-29

2.  Different bleeding patterns with the use of levonorgestrel intrauterine system: are they associated with changes in uterine artery blood flow?

Authors:  Carlo Bastianelli; Manuela Farris; Stefania Rapiti; Roberta Bruno Vecchio; Giuseppe Benagiano
Journal:  Biomed Res Int       Date:  2014-04-23       Impact factor: 3.411

3.  Chronic Systemic Toxicity Study of Copper Intrauterine Devices in Female Wistar Rats.

Authors:  Xia Zhao; Qian Liu; Haixiang Sun; Yali Hu; Zhaoxu Wang
Journal:  Med Sci Monit       Date:  2017-08-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.