Prospective study of cone-beam computed tomography image-guided radiotherapy for prone accelerated partial breast irradiation.

Gabor Jozsef1, J Keith DeWyngaert, Stewart J Becker, Stella Lymberis, Silvia C Formenti.   

Abstract

PURPOSE: To report setup variations during prone accelerated partial breast irradiation (APBI).
METHODS: New York University (NYU) 07-582 is an institutional review board-approved protocol of cone-beam computed tomography (CBCT) to deliver image-guided ABPI in the prone position. Eligible are postmenopausal women with pT1 breast cancer excised with negative margins and no nodal involvement. A total dose of 30 Gy in five daily fractions of 6 Gy are delivered to the planning target volume (the tumor cavity with 1.5-cm margin) by image-guided radiotherapy. Patients are set up prone, on a dedicated mattress, used for both simulation and treatment. After positioning with skin marks and lasers, CBCTs are performed and the images are registered to the planning CT. The resulting shifts (setup corrections) are recorded in the three principal directions and applied. Portal images are taken for verification. If they differ from the planning digital reconstructed radiographs, the patient is reset, and a new CBCT is taken.
RESULTS: 70 consecutive patients have undergone a total of 343 CBCTs: 7 patients had four of five planned CBCTs performed. Seven CBCTs (2%) required to be repeated because of misalignment in the comparison between portal and digital reconstructed radiograph image after the first CBCT. The mean shifts and standard deviations in the anterior-posterior (AP), superior-inferior (SI), and medial-lateral (ML) directions were -0.19 (0.54), -0.02 (0.33), and -0.02 (0.43) cm, respectively. The average root mean squares of the daily shifts were 0.50 (0.28), 0.29 (0.17), and 0.38 (0.20). A conservative margin formula resulted in a recommended margin of 1.26, 0.73, 0.96 cm in the AP, SI, and ML directions.
CONCLUSION: CBCTs confirmed that the NYU prone APBI setup and treatment technique are reproducible, with interfraction variation comparable to those reported for supine setup. The currently applied margin (1.5 cm) adequately compensates for the setup variation detected.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21570210     DOI: 10.1016/j.ijrobp.2010.11.029

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  16 in total

1.  Setup accuracy for prone and supine whole breast irradiation.

Authors:  Thomas Mulliez; Akos Gulyban; Tom Vercauteren; Annick van Greveling; Bruno Speleers; Wilfried De Neve; Liv Veldeman
Journal:  Strahlenther Onkol       Date:  2016-02-10       Impact factor: 3.621

2.  Implementation of image-guided intensity-modulated accelerated partial breast irradiation : Three-year results of a phase II clinical study.

Authors:  Norbert Mészáros; Tibor Major; Gábor Stelczer; Zoltán Zaka; Emőke Mózsa; Dávid Pukancsik; Zoltán Takácsi-Nagy; János Fodor; Csaba Polgár
Journal:  Strahlenther Onkol       Date:  2016-11-21       Impact factor: 3.621

Review 3.  Late complications of radiation therapy for breast cancer: evolution in techniques and risk over time.

Authors:  Zachary Brownlee; Rashi Garg; Matthew Listo; Peter Zavitsanos; David E Wazer; Kathryn E Huber
Journal:  Gland Surg       Date:  2018-08

4.  Prone accelerated partial breast irradiation after breast-conserving surgery: five-year results of 100 patients.

Authors:  Silvia C Formenti; Howard Hsu; Maria Fenton-Kerimian; Daniel Roses; Amber Guth; Gabor Jozsef; Judith D Goldberg; J Keith Dewyngaert
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-04-09       Impact factor: 7.038

5.  Improved cone-beam computed tomography in supine and prone breast radiotherapy. Surface reconstruction, radiation exposure, and clinical workflow.

Authors:  A De Puysseleyr; T Mulliez; A Gulyban; E Bogaert; T Vercauteren; T Van Hoof; J Van de Velde; R Van Den Broecke; C De Wagter; W De Neve
Journal:  Strahlenther Onkol       Date:  2013-10-03       Impact factor: 3.621

6.  The role of a prone setup in breast radiation therapy.

Authors:  Nelly Huppert; Gabor Jozsef; Keith Dewyngaert; Silvia Chiara Formenti
Journal:  Front Oncol       Date:  2011-10-11       Impact factor: 6.244

Review 7.  Image-guided radiotherapy for cardiac sparing in patients with left-sided breast cancer.

Authors:  Claire Lemanski; Juliette Thariat; Federico L Ampil; Satya Bose; Jacqueline Vock; Rick Davis; Alexander Chi; Suresh Dutta; William Woods; Anand Desai; Juan Godinez; Ulf Karlsson; Melissa Mills; Nam Phong Nguyen; Vincent Vinh-Hung
Journal:  Front Oncol       Date:  2014-09-23       Impact factor: 6.244

8.  Preplanning prediction of the left anterior descending artery maximum dose based on patient, dosimetric, and treatment planning parameters.

Authors:  Benjamin T Cooper; Xiaochun Li; Samuel M Shin; Aram S Modrek; Howard C Hsu; J K DeWyngaert; Gabor Jozsef; Stella C Lymberis; Judith D Goldberg; Silvia C Formenti
Journal:  Adv Radiat Oncol       Date:  2016-08-09

9.  Prone versus supine position for adjuvant breast radiotherapy: a prospective study in patients with pendulous breasts.

Authors:  Marco Krengli; Laura Masini; Tina Caltavuturo; Carla Pisani; Giuseppina Apicella; Eleonora Negri; Letizia Deantonio; Marco Brambilla; Giuseppina Gambaro
Journal:  Radiat Oncol       Date:  2013-10-08       Impact factor: 3.481

10.  A dosimetry study precisely outlining the heart substructure of left breast cancer patients using intensity-modulated radiation therapy.

Authors:  Ling-li Fan; Yang-kun Luo; Jing-hui Xu; Ling He; Jie Wang; Xiao-bo Du
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.