Literature DB >> 21570208

Alternated prone and supine whole-breast irradiation using IMRT: setup precision, respiratory movement and treatment time.

Liv Veldeman1, Werner De Gersem, Bruno Speleers, Bart Truyens, Annick Van Greveling, Rudy Van den Broecke, Wilfried De Neve.   

Abstract

PURPOSE: The objective of this study was to compare setup precision, respiration-related breast movement and treatment time between prone and supine positions for whole-breast irradiation. METHODS AND MATERIALS: Ten patients with early-stage breast carcinoma after breast-conserving surgery were treated with prone and supine whole breast-irradiation in a daily alternating schedule. Setup precision was monitored using cone-beam computed tomography (CBCT) imaging. Respiration-related breast movement in the vertical direction was assessed by magnetic sensors. The time needed for patient setup and for the CBCT procedure, the beam time, and the length of the whole treatment slot were also recorded.
RESULTS: Random and systematic errors were not significantly different between positions in individual patients for each of the three axes (left-right, longitudinal, and vertical). Respiration-related movement was smaller in prone position, but about 80% of observations showed amplitudes <1 mm in both positions. Treatment slots were longer in prone position (21.2 ± 2.5 min) than in supine position (19.4 ± 0.8 min; p = 0.044).
CONCLUSION: Comparison of setup precision between prone and supine position in the same patient showed no significant differences in random and systematic errors. Respiratory movement was smaller in prone position. The longer treatment slots in prone position can probably be attributed to the higher repositioning need. Copyright Â
© 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21570208     DOI: 10.1016/j.ijrobp.2010.10.070

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  19 in total

1.  Respiratory Motion, Anterior Heart Displacement and Heart Dosimetry: Comparison Between Prone (Pr) and Supine (Su) Whole Breast Irradiation.

Authors:  Ferenc Lakosi; Akos Gulyban; Levente Janvary; Selma Ben-Mustapha Simoni; Nicolas Jansen; Laurence Seidel; Arpad Kovacs; Peter Vavassis; Philippe Coucke
Journal:  Pathol Oncol Res       Date:  2015-04-04       Impact factor: 3.201

2.  Set-up uncertainty during breast radiotherapy. Image-guided radiotherapy for patients with initial extensive variation.

Authors:  D S Yang; W S Yoon; S Y Chung; J A Lee; S Lee; Y J Park; C Y Kim; G S Son
Journal:  Strahlenther Onkol       Date:  2013-02-28       Impact factor: 3.621

3.  Setup accuracy for prone and supine whole breast irradiation.

Authors:  Thomas Mulliez; Akos Gulyban; Tom Vercauteren; Annick van Greveling; Bruno Speleers; Wilfried De Neve; Liv Veldeman
Journal:  Strahlenther Onkol       Date:  2016-02-10       Impact factor: 3.621

4.  Reproducibility of deep inspiration breath hold for prone left-sided whole breast irradiation.

Authors:  Thomas Mulliez; Liv Veldeman; Tom Vercauteren; Werner De Gersem; Bruno Speleers; Annick Van Greveling; Dieter Berwouts; Vincent Remouchamps; Rudy Van den Broecke; Wilfried De Neve
Journal:  Radiat Oncol       Date:  2015-01-09       Impact factor: 3.481

5.  Whole breast radiotherapy in prone and supine position: is there a place for multi-beam IMRT?

Authors:  Thomas Mulliez; Bruno Speleers; Indira Madani; Werner De Gersem; Liv Veldeman; Wilfried De Neve
Journal:  Radiat Oncol       Date:  2013-06-24       Impact factor: 3.481

6.  Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy.

Authors:  Vikneswary Batumalai; Penny Phan; Callie Choong; Lois Holloway; Geoff P Delaney
Journal:  J Med Radiat Sci       Date:  2016-05-31

7.  Efficacy and workload analysis of a fixed vertical couch position technique and a fixed-action-level protocol in whole-breast radiotherapy.

Authors:  Saskia Petillion; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

8.  Development of the breast immobilization system in prone setup: The effect of bra in prone position to improve the breast setup error.

Authors:  Mariko Kawamura; Yoshikazu Maeda; Kazutaka Yamamoto; Shigeyuki Takamatsu; Yoshitaka Sato; Hiroki Minami; Yusuke Saga; Kyo Kume; Yuji Tameshige; Makoto Sasaki; Hiroyasu Tamamura; Kouji Ohta; Yoshiyuki Itoh; Shinji Naganawa
Journal:  J Appl Clin Med Phys       Date:  2017-06-08       Impact factor: 2.102

9.  Prone breast forward intensity-modulated radiotherapy for Asian women with early left breast cancer: factors for cardiac sparing and clinical outcomes.

Authors:  Jenny Ling-Yu Chen; Jason Chia-Hsien Cheng; Sung-Hsin Kuo; Hsing-Min Chan; Yu-Sen Huang; Yu-Hsuan Chen
Journal:  J Radiat Res       Date:  2013-03-15       Impact factor: 2.724

10.  Surface imaging-based analysis of intrafraction motion for breast radiotherapy patients.

Authors:  David B Wiant; Stacy Wentworth; Jacqueline M Maurer; Caroline L Vanderstraeten; Jonathon A Terrell; Benjamin J Sintay
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

View more