Literature DB >> 21569746

Systemic hypersensitivity reaction (without cutaneous manifestations) to an implantable cardioverter-defibrillator.

Israel D Andrews1, Pamela Scheinman.   

Abstract

Implantable cardiac devices play a significant role in decreasing the morbidity and mortality in patients with cardiovascular disease. Tissue-device interactions leading to systemic hypersensitivity are rarely reported or are perhaps misdiagnosed as infectious in origin. We report the case of a 51-year-old female who underwent placement of an implantable cardiac defibrillator (ICD) and a biventricular pacemaker and who immediately postoperatively experienced sepsislike symptoms without any identifiable causative pathogens and without any dermatitis. Patch testing revealed an extreme reaction to cobalt confirmed as present in the defibrillator. Removal of the ICD led to the complete resolution of her symptoms. Patch testing helped guide the construction of a gold-coated ICD, which was implanted in the patient. The patient has remained symptom free after implantation of this gilded ICD.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21569746

Source DB:  PubMed          Journal:  Dermatitis        ISSN: 1710-3568            Impact factor:   4.845


  5 in total

Review 1.  Systemic contact dermatitis and allergy to biomedical devices.

Authors:  Marcella Aquino; Tania Mucci
Journal:  Curr Allergy Asthma Rep       Date:  2013-10       Impact factor: 4.806

2.  Kounis syndrome induced by amoxicillin following vasospastic coronary event in a 22-year-old patient: a case report.

Authors:  Snehasis Pradhan; Martin Christ; Hans-Joachim Trappe
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

3.  Sugammadex-induced atropine-resistant bradycardia: clinical, pathophysiologic, and electrocardiographic considerations.

Authors:  Nicholas G Kounis; Ioanna Koniari; George D Soufras; Grigorios Tsigkas; Panagiotis Plotas; Periklis Davlouros; George Hahalis
Journal:  JA Clin Rep       Date:  2020-05-07

Review 4.  Contact dermatitis.

Authors:  Pamela L Scheinman; Marc Vocanson; Jacob P Thyssen; Jeanne Duus Johansen; Rosemary L Nixon; Kate Dear; Nina C Botto; Johanna Morot; Ari M Goldminz
Journal:  Nat Rev Dis Primers       Date:  2021-05-27       Impact factor: 52.329

5.  Hypersensitivity to material and environmental burden as a possible cause of late complications of cardiac implantable electronic devices.

Authors:  Jan Manoušek; Irena Andršová; Vera Stejskal; Jitka Vlašínová; Milan Sepši; Jan Kuta; Jana Klánová; Michal Mazík; Jirí Jarkovský; Lenka Šnajdrová; Klára Benešová; Tomáš Novotný; Andrea Zadáková; Jindrich Špinar
Journal:  Europace       Date:  2018-09-01       Impact factor: 5.214

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.