Literature DB >> 21568982

Comparison of the i-gel and the LMA-Unique laryngeal mask airway in patients with mild to moderate obesity during elective short-term surgery.

U Weber1, R Oguz, L A Potura, O Kimberger, A Kober, E Tschernko.   

Abstract

The aim of our study was to compare leakage pressure, ease and time of insertion of the i-gel and the LMA-Unique laryngeal mask airway in patients with mild to moderate obesity during elective short-term surgery. In this prospective, randomised crossover trial, we included patients with a body mass index (BMI) >25 and <35 kg.m(-2) , and , age >18 years, undergoing elective surgery in the supine position with an expected duration of surgery <2 h. Leakage pressures, insertion difficulty, time and number of insertion attempts were evaluated. We included 50 patients consisting of 29 mildly (BMI>25 and < 30 kg.mg(-2) ) and 21 moderately (BMI>30 and < 35 kg.mg(-2) ) obese patients. Mean (SD) leakage pressures were 23.7 (9.2) cmH₂O (i-gel) and 17.4 (7.0) cmH₂O (LMA-Unique) (p<0.01). Subgroup analyses showed leakage pressures of 22.2 (9.4) cmH₂O (i-gel) and 17.5 (7.5) cmH₂O (LMA-Unique) (p=0.013) in the mild subgroup, and 25.7 (8.6) cmH₂O (i-gel) and 17.0 (6.2) cmH₂O (LMA-Unique) (p<0.01), in the moderate subgroup. Insertion of the i-gel was associated with significantly higher leakage pressures compared with the LMA-Unique in mildly and moderately obese patients.
© 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2011        PMID: 21568982     DOI: 10.1111/j.1365-2044.2011.06682.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  I-gel versus laryngeal mask airway-Proseal: Comparison of two supraglottic airway devices in short surgical procedures.

Authors:  Poonam A Jadhav; Naina P Dalvi; Bharati A Tendolkar
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Apr-Jun

2.  Comparison of I-gel for general anesthesia in obese and nonobese patients.

Authors:  Rati Prabha; Rajesh Raman; Mohammad Parvez Khan; Dinesh Kaushal; Ahsan Khaliq Siddiqui; Haider Abbas
Journal:  Saudi J Anaesth       Date:  2018 Oct-Dec

3.  Clinical performance of the LMA Protector™ airway in moderately obese patients.

Authors:  Ina Ismiarti Shariffuddin; Sook Hui Chaw; Ling Wei Ng; Ching Hooi Lim; Mohd Fitry Zainal Abidin; Wan A Wan Zakaria; Wendy H Teoh
Journal:  BMC Anesthesiol       Date:  2020-07-31       Impact factor: 2.217

4.  Influence of head and neck positions on oropharyngeal seal pressure with Baska mask® versus I-gel™; A randomised clinical study.

Authors:  Gurkaran Kaur Sidhu; Seema Jindal; Rupali Mahajan; Sheetal Bhagat
Journal:  Indian J Anaesth       Date:  2020-07-31
  4 in total