OBJECT: The goal of this study was to assess whether a stable but nonrigid nonfusion implant can stabilize the spine in degenerative diseases and also prevent instability following decompression. Instrumented spondylodesis is a recognized surgical treatment in degenerative disease of the lumbar spine. However, pain can develop at the bone graft donor site and the operative trauma can be very stressful in elderly patients, and it is suspected that there may be increased degenerative changes in the adjacent segments. In 2002, a nonrigid but rotationally stable pedicle screw and rod system was introduced, which could be used without additional fusion (referred to hereafter as the Cosmic system).
METHODS: A total of 139 patients with degenerative disease of the lumbar spine underwent spinal stabilization with the Cosmic system without additional spondylodesis. Seventy patients had an additional decompression. The minimum follow-up was 2 years. The perioperative course, the clinical results, and the erect anteroposterior and lateral radiographs were recorded and compared with the preoperative data. The data were obtained from 6 different spine centers in Europe and documented on an Internet platform.
RESULTS: The Oswestry Disability Index score improved from 48.9% to 22.5%, and the visual analog scale score decreased from 7.3 to 2.5. Lumbar lordosis did not change, nor did the adjacent disc height. Eleven patients underwent revision, 4 of them for implant failure. Of the 139 patients, 110 assessed the result as excellent, very good, or good; 24 as fair; and 5 as poor. A total of 122 patients would undergo surgery again. There were no significant differences between patients with or without an additional decompression.
CONCLUSIONS: The Cosmic system is a stable but nonrigid posterior nonfusion system. Implant complications are low and the clinical outcome is good. Longer follow-up is necessary to confirm the 2-year results.

Entities:  

Mesh:

Year:  2011        PMID: 21568650     DOI: 10.3171/2011.3.SPINE0969

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  3 in total

1.  Which radiographic parameters are linked to failure of a dynamic spinal implant?

Authors:  Eike Hoff; Patrick Strube; Antonius Rohlmann; Christian Gross; Michael Putzier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Simple facet joint repair with dynamic pedicular system: Technical note and case series.

Authors:  Ali Fahir Ozer; Tuncer Suzer; Mehdi Sasani; Tunc Oktenoglu; Phillip Cezayirli; Hosein Jafari Marandi; Deniz Ufuk Erbulut
Journal:  J Craniovertebr Junction Spine       Date:  2015 Apr-Jun

3.  A short history of posterior dynamic stabilization.

Authors:  Cengiz Gomleksiz; Mehdi Sasani; Tunc Oktenoglu; Ali Fahir Ozer
Journal:  Adv Orthop       Date:  2012-12-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.