Literature DB >> 21558947

Photoelastic analysis of implant-retained and conventional obturator prostheses with different attachment systems and soft relining.

Paula do Prado Ribeiro1, Marcelo Coelho Goiato, Eduardo Pizza Pellizzer, Aldiéris Alves Pesqueira, Marcela Filiè Haddad, Stefan Fiuza de Carvalho Dekon, Daniela Micheline dos Santos.   

Abstract

Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21558947     DOI: 10.1097/SCS.0b013e31820f3473

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  3 in total

1.  Stress distribution of multiple implant-supported prostheses: Photoelastic and strain gauge analyses of external hexagon and morse taper connections.

Authors:  Ana-Beatriz-Bueno-Carlini Bittencourt; Erica-de Oliveira-Paiva Rezende; Marcio Campaner; Sandro-Basso Bitencourt; Daniela-Micheline Dos Santos; Aldiéris-Alves Pesqueira; Marcelo-Coelho Goiato
Journal:  J Clin Exp Dent       Date:  2022-03-01

2.  Full Mouth Reconstruction of a Skeletal Class II Division 1 Patient with Adenoid Cystic Carcinoma Using an Interim Immediate Obturator and a Definitive Obturator.

Authors:  Mehran Bahrami; Seyed Mehran Falahchai
Journal:  Case Rep Dent       Date:  2017-04-04

3.  Stress distribution in fixed mandibular prostheses fabricated by CAD/CAM and conventional techniques: Photoelastic and strain gauge analyses.

Authors:  Rodrigo-Antonio de Medeiros; Daniela-Micheline Dos Santos; Aldiéris-Alves Pesqueira; Marcio Campaner; Sandro-Basso Bitencourt; Emily-Vivianne-Freitas da Silva; Marcelo-Coelho Goiato
Journal:  J Clin Exp Dent       Date:  2019-09-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.