Literature DB >> 21552646

Heart failure: comparison between six-minute walk test and cardiopulmonary test.

Eduardo Elias Vieira de Carvalho1, Daniela Caetano Costa, Júlio César Crescêncio, Giovani Luiz De Santi, Valéria Papa, Fabiana Marques, André Schmidt, José Antonio Marin-Neto, Marcus Vinícius Simões, Lourenço Gallo Junior.   

Abstract

BACKGROUND: Chronic heart failure (HF) is a syndrome characterized by reduced cardiac output in relation to the metabolic needs of the organism, as well as metabolic and neurohormonal axis abnormalities. Symptoms such as fatigue and dyspnoea are notorious and stress tests are widely used to assess functional capacity, prognosis and effectiveness of therapeutic interventions in this syndrome.
OBJECTIVE: To evaluate the reproducibility of the six-minute walk test (6MW) in patients with HF and correlate the magnitude of the variables reached at peak exercise of the 6MWT with a cardiopulmonary exercise test (CPET).
METHODS: We studied 16 patients (12 men and 4 women) diagnosed with HF FC I-II (NYHA). The volunteers underwent two 6MWT (6MWT'1 and 6MWT'2) with 30-minute interval between them; then, they underwent a maximum CPET.
RESULTS: All variables obtained in the two 6MWT' proved to be significant with high correlations: distance walked (DW) (r = 0.93, p < 0.0001), heart rate (HR) (r = 0.89, p < 0.0001), oxygen consumption (VO2) (r = 0.93, p < 0.0001) and scale of perceived exertion (r = 0.85, p < 0.0001). In turn, all variables analyzed in the 6MWT' showed significant and moderate correlations with the variables obtained from the CPET, namely: peak HR (r = 0.66; p = 0.005); VO2 (r = 0.57; p = 0.02) and VO2 in the CPET and DT in the 6MWT'2 (r = 0.70; p = 0.002).
CONCLUSION: The 6MWT was reproducible in this group of patients with HF (NYHA - I-II) and correlated with the CPET. Therefore, it is a tool for reliable evaluation, and a suitable, safe and low-cost alternative for the prescription of aerobic exercise in patients with HF.

Entities:  

Mesh:

Year:  2011        PMID: 21552646     DOI: 10.1590/s0066-782x2011005000056

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  8 in total

Review 1.  End points in heart failure-are we doing it right?

Authors:  Luxitaa Goenka; Melvin George; Sandhiya Selvarajan
Journal:  Eur J Clin Pharmacol       Date:  2017-03-09       Impact factor: 2.953

2.  6-min walk test provides prognostic utility comparable to cardiopulmonary exercise testing in ambulatory outpatients with systolic heart failure.

Authors:  Daniel E Forman; Jerome L Fleg; Dalane W Kitzman; Clinton A Brawner; Ann M Swank; Robert S McKelvie; Robert M Clare; Stephen J Ellis; Mark E Dunlap; Vera Bittner
Journal:  J Am Coll Cardiol       Date:  2012-11-21       Impact factor: 24.094

3.  Intensity and physiological responses to the 6-minute walk test in middle-aged and older adults: a comparison with cardiopulmonary exercise testing.

Authors:  E F Sperandio; R L Arantes; A C Matheus; R P Silva; V T Lauria; M Romiti; A R T Gagliardi; V Z Dourado
Journal:  Braz J Med Biol Res       Date:  2015-02-24       Impact factor: 2.590

Review 4.  Non-Invasive Ventilation in Patients with Heart Failure: A Systematic Review and Meta-Analysis.

Authors:  Hugo Souza Bittencourt; Helena França Correia Dos Reis; Melissa Santos Lima; Mansueto Gomes
Journal:  Arq Bras Cardiol       Date:  2017-01-16       Impact factor: 2.000

Review 5.  6-minute walking test: a useful tool in the management of heart failure patients.

Authors:  Sophia Giannitsi; Mara Bougiakli; Aris Bechlioulis; Anna Kotsia; Lampros K Michalis; Katerina K Naka
Journal:  Ther Adv Cardiovasc Dis       Date:  2019 Jan-Dec

6.  Epidemiological profile, cardiopulmonary fitness and health-related quality of life of patients with heart failure: a longitudinal study.

Authors:  Paula Cristina Silva; Omar Pereira de Almeida Neto; Elmiro Santos Resende
Journal:  Health Qual Life Outcomes       Date:  2021-04-23       Impact factor: 3.186

7.  Diastolic function is associated with quality of life and exercise capacity in stable heart failure patients with reduced ejection fraction.

Authors:  M F Bussoni; G N Guirado; M G Roscani; B F Polegato; L S Matsubara; S G Z Bazan; B B Matsubara
Journal:  Braz J Med Biol Res       Date:  2013-08-30       Impact factor: 2.590

8.  Vitamin D insufficiency is associated with lower physical function in patients with heart failure and diabetes.

Authors:  M R Lopes; Paula A B Ribeiro; Priscila Ledur; Gabriela C Souza; Nadine Clausell; Beatriz D Schaan
Journal:  J Diabetes Res       Date:  2014-08-25       Impact factor: 4.011

  8 in total