Literature DB >> 21551012

Less is more: standard warm-up causes fatigue and less warm-up permits greater cycling power output.

Elias K Tomaras1, Brian R MacIntosh.   

Abstract

The traditional warm-up (WU) used by athletes to prepare for a sprint track cycling event involves a general WU followed by a series of brief sprints lasting ≥ 50 min in total. A WU of this duration and intensity could cause significant fatigue and impair subsequent performance. The purpose of this research was to compare a traditional WU with an experimental WU and examine the consequences of traditional and experimental WU on the 30-s Wingate test and electrically elicited twitch contractions. The traditional WU began with 20 min of cycling with a gradual intensity increase from 60% to 95% of maximal heart rate; then four sprints were performed at 8-min intervals. The experimental WU was shorter with less high-intensity exercise: intensity increased from 60% to 70% of maximal heart rate over 15 min; then just one sprint was performed. The Wingate test was conducted with a 1-min lead-in at 80% of optimal cadence followed by a Wingate test at optimal cadence. Peak active twitch torque was significantly lower after the traditional than experimental WU (86.5 ± 3.3% vs. 94.6 ± 2.4%, P < 0.05) when expressed as percentage of pre-WU amplitude. Wingate test performance was significantly better (P < 0.01) after experimental WU (peak power output = 1,390 ± 80 W, work = 29.1 ± 1.2 kJ) than traditional WU (peak power output = 1,303 ± 89 W, work = 27.7 ± 1.2 kJ). The traditional track cyclist's WU results in significant fatigue, which corresponds with impaired peak power output. A shorter and lower-intensity WU permits a better performance.

Entities:  

Mesh:

Year:  2011        PMID: 21551012     DOI: 10.1152/japplphysiol.00253.2011

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  8 in total

1.  Warm-up effects on muscle oxygenation, metabolism and sprint cycling performance.

Authors:  Anna Wittekind; Chris E Cooper; Clare E Elwell; Terence S Leung; Ralph Beneke
Journal:  Eur J Appl Physiol       Date:  2012-01-03       Impact factor: 3.078

Review 2.  Warm-Up Strategies for Sport and Exercise: Mechanisms and Applications.

Authors:  Courtney J McGowan; David B Pyne; Kevin G Thompson; Ben Rattray
Journal:  Sports Med       Date:  2015-11       Impact factor: 11.136

Review 3.  Warm-up and performance in competitive swimming.

Authors:  Henrique P Neiva; Mário C Marques; Tiago M Barbosa; Mikel Izquierdo; Daniel A Marinho
Journal:  Sports Med       Date:  2014-03       Impact factor: 11.136

4.  Effects of Warm-Up, Post-Warm-Up, and Re-Warm-Up Strategies on Explosive Efforts in Team Sports: A Systematic Review.

Authors:  Luís Miguel Silva; Henrique Pereira Neiva; Mário Cardoso Marques; Mikel Izquierdo; Daniel Almeida Marinho
Journal:  Sports Med       Date:  2018-10       Impact factor: 11.136

5.  The Acute Effects of Static Stretching Compared to Dynamic Stretching with and without an Active Warm up on Anaerobic Performance.

Authors:  Bradley J Kendall
Journal:  Int J Exerc Sci       Date:  2017-01-01

6.  Effects of self-myofascial release interventions with or without sliding pressures on skin temperature, range of motion and perceived well-being: a randomized control pilot trial.

Authors:  Yann Kerautret; Aymeric Guillot; Carole Eyssautier; Guillaume Gibert; Franck Di Rienzo
Journal:  BMC Sports Sci Med Rehabil       Date:  2021-04-22

7.  Testing, Training, and Optimising Performance of Track Cyclists: A Systematic Mapping Review.

Authors:  Antony M J Stadnyk; Franco M Impellizzeri; Jamie Stanley; Paolo Menaspà; Katie M Slattery
Journal:  Sports Med       Date:  2021-09-30       Impact factor: 11.136

8.  Validity and Reliability of the 30-s Continuous Jump for Anaerobic Power and Capacity Assessment in Combat Sport.

Authors:  Drazen Čular; Vladimir Ivančev; Alessandro M Zagatto; Mirjana Milić; Tea Beslija; Maha Sellami; Johnny Padulo
Journal:  Front Physiol       Date:  2018-05-15       Impact factor: 4.566

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.