Literature DB >> 21550911

In vivo assessment of optimal viewing angles from X-ray coronary angiography.

Shengxian Tu1, Peiyuan Hao, Gerhard Koning, Xianglong Wei, Xudong Song, Aihua Chen, Johan H C Reiber.   

Abstract

AIMS: To propose and validate a novel approach to determine the optimal angiographic viewing angles for a selected coronary (target) segment from X-ray coronary angiography, without the need to reconstruct the entire coronary tree in three-dimensions (3D), such that subsequent interventions are carried out from the best view. METHODS AND
RESULTS: The approach starts with standard quantitative coronary angiography (QCA) of the target vessel in two angiographic views. Next, the target vessel is reconstructed in 3D, and in a very simple and intuitive manner, the possible overlap of the target vessel and other vessel segments can be assessed, resulting in the best view with minimum foreshortening and overlap. A retrospective study including 67 patients was set up for the validation. The overlap prediction result was compared with the true overlap on the available angiographic views (TEST views). The foreshortening for the views proposed by the new approach software viewing angle (SVA) and the views used during the stent deployment software viewing angle (EVA) were compared. Two experienced interventional cardiologists visually evaluated the success of SVA with respect to EVA. The evaluation results were graded into five values ranging from -2 to 2. The overlap prediction algorithm successfully predicted the overlap condition for all 235 TEST views. EVA was associated with more foreshortening than SVA (8.9% ± 8.2% vs. 1.6% ± 1.5%, p<0.001). The average evaluated point for the success of SVA was 0.94 ± 0.80 (p <0.001), indicating that the evaluators were in favor of the optimal views determined by the proposed approach versus the views used during the actual intervention.
CONCLUSIONS: The proposed approach is able to accurately and quickly determine the optimal viewing angles for the online support of coronary interventions.

Entities:  

Mesh:

Year:  2011        PMID: 21550911     DOI: 10.4244/EIJV7I1A19

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  7 in total

Review 1.  QCA, IVUS and OCT in interventional cardiology in 2011.

Authors:  Johan H C Reiber; Shengxian Tu; Joan C Tuinenburg; Gerhard Koning; Johannes P Janssen; Jouke Dijkstra
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

2.  Differences of side branch jailing between left main-left anterior descending artery stenting and left main-left circumflex artery stenting with Nobori biolimus-eluting stent.

Authors:  Fumiaki Nakao; Takayuki Okamura; Takeshi Suetomi; Jutaro Yamada; Takeshi Nakamura; Tooru Ueda; Takamasa Oda; Masashi Kanemoto; Yasuhiro Ikeda; Takashi Fujii; Masafumi Yano
Journal:  Heart Vessels       Date:  2016-02-15       Impact factor: 2.037

3.  In vivo assessment of bifurcation optimal viewing angles and bifurcation angles by three-dimensional (3D) quantitative coronary angiography.

Authors:  Shengxian Tu; Jing Jing; Niels R Holm; Kevin Onsea; Tao Zhang; Tom Adriaenssens; Christophe Dubois; Walter Desmet; Leif Thuesen; Yundai Chen; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-15       Impact factor: 2.357

4.  In vivo comparison of arterial lumen dimensions assessed by co-registered three-dimensional (3D) quantitative coronary angiography, intravascular ultrasound and optical coherence tomography.

Authors:  Shengxian Tu; Liang Xu; Jurgen Ligthart; Bo Xu; Karen Witberg; Zhongwei Sun; Gerhard Koning; Johan H C Reiber; Evelyn Regar
Journal:  Int J Cardiovasc Imaging       Date:  2012-01-20       Impact factor: 2.357

5.  Accuracy and reproducibility of fast fractional flow reserve computation from invasive coronary angiography.

Authors:  A R van Rosendael; G Koning; A C Dimitriu-Leen; J M Smit; J M Montero-Cabezas; F van der Kley; J W Jukema; J H C Reiber; J J Bax; A J H A Scholte
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-22       Impact factor: 2.357

6.  Three-dimensional evaluation of the spatial morphology of stented coronary artery segments in relation to restenosis.

Authors:  Áron Üveges; Csaba Jenei; Tibor Kiss; Zoltán Szegedi; Balázs Tar; Gábor Tamás Szabó; Dániel Czuriga; Zsolt Kőszegi
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-24       Impact factor: 2.357

7.  An adaptive optimal viewing angle determination algorithm for TEVAR operation.

Authors:  Weiya Sun; Guanyu Yang; Yang Chen; Huazhong Shu
Journal:  BMC Med Imaging       Date:  2021-10-02       Impact factor: 1.930

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.