Literature DB >> 21550905

Effect of paclitaxel elution from reservoirs with bioabsorbable polymer compared to a bare metal stent for the elective percutaneous treatment of de novo coronary stenosis: the EUROSTAR-II randomised clinical trial.

Sigmund Silber1, Juan Luis Gutiérrez-Chico, Steffen Behrens, Bernhard Witzenbichler, Marcus Wiemer, Stefan Hoffmann, Ton Slagboom, Darius Harald, Harry Suryapranata, Christoph Nienaber, Bernard Chevalier, Patrick W Serruys.   

Abstract

AIMS: To compare the angiographic and clinical performance of a paclitaxel-eluting stent using reservoirs technology and a bioabsorbable polymer, without surface coating (CoStar), vs. an equivalent bare metal stent (BMS) using an identical metallic platform. METHODS AND
RESULTS: Three hundred and three (303) patients (335 lesions) with de novo coronary artery stenosis suitable for elective percutaneous treatment were randomised in an international multicentre single-blind trial to receive the CoStar stent (n=152) or the equivalent BMS (n=151). At eight months, the primary endpoint of in-segment binary restenosis was significantly lower in the CoStar than in the BMS group (17.6 vs. 30.3%, p=0.029). In-stent late loss (0.41 vs. 0.81 mm; p<0.0001) and all the other angiographic secondary endpoints also favoured CoStar. The composite of cardiac death, myocardial infarction related to the target vessel and target lesion revascularisation was significantly lower at eight months in the CoStar arm (19.7 vs. 29.1%; hazard ratio 0.54, 95% CI: 0.34-0.87; p=0.010), mainly due to lower incidence of target lesion revascularisation (15.1 vs. 26.5%; 95% CI: hazard ratio 0.45, 95% CI: 0.27-0.76; p=0.002).
CONCLUSIONS: As compared with a bare metal stent of identical design, the paclitaxel elution from reservoirs results in significantly less binary restenosis, less late loss and lower revascularisation rates at eight months. Therefore, based on these data, the CoStar paclitaxel-eluting stent was found to be effective and safe.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21550905     DOI: 10.4244/EIJV7I1A13

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

1.  Paclitaxel Drug-eluting Tracheal Stent Could Reduce Granulation Tissue Formation in a Canine Model.

Authors:  Ting Wang; Jie Zhang; Juan Wang; Ying-Hua Pei; Xiao-Jian Qiu; Yu-Ling Wang
Journal:  Chin Med J (Engl)       Date:  2016-11-20       Impact factor: 2.628

2.  Safety and efficacy of biodegradable drug-eluting vs. bare metal stents: a meta-analysis from randomized trials.

Authors:  Yangguang Yin; Yao Zhang; Xiaohui Zhao
Journal:  PLoS One       Date:  2014-06-19       Impact factor: 3.240

  2 in total