Literature DB >> 21550683

A new fibre optic pulse oximeter probe for monitoring splanchnic organ arterial blood oxygen saturation.

M Hickey1, N Samuels, N Randive, R Langford, P A Kyriacou.   

Abstract

A new, continuous method of monitoring splanchnic organ oxygen saturation (SpO(2)) would make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischaemia, and, ultimately, death. In an attempt to provide such a device, a new fibre optic based reflectance pulse oximeter probe and processing system were developed followed by an in vivo evaluation of the technology on seventeen patients undergoing elective laparotomy. Photoplethysmographic (PPG) signals of good quality and high signal-to-noise ratio were obtained from the small bowel, large bowel, liver and stomach. Simultaneous peripheral PPG signals from the finger were also obtained for comparison purposes. Analysis of the amplitudes of all acquired PPG signals indicated much larger amplitudes for those signals obtained from splanchnic organs than those obtained from the finger. Estimated SpO(2) values for splanchnic organs showed good agreement with those obtained from the finger fibre optic probe and those obtained from a commercial device. These preliminary results suggest that a miniaturized 'indwelling' fibre optic sensor may be a suitable method for pre-operative and post-operative evaluation of splanchnic organ SpO(2) and their health.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21550683     DOI: 10.1016/j.cmpb.2011.03.019

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  3 in total

1.  Machine Perfusion of Liver Grafts With Implantable Oxygen Biosensors: Proof of Concept Study in a Rodent Model.

Authors:  Uwe Scheuermann; Mohamed M Ibrahim; John Yerxa; William Parker; Matthew G Hartwig; Bruce Klitzman; Andrew S Barbas
Journal:  Transplant Direct       Date:  2019-06-21

2.  Optical Fibre-Based Pulse Oximetry Sensor with Contact Force Detection.

Authors:  Chong Liu; Ricardo Correia; Hattan Khaled Ballaji; Serhiy Korposh; Barrie R Hayes-Gill; Stephen P Morgan
Journal:  Sensors (Basel)       Date:  2018-10-26       Impact factor: 3.576

Review 3.  Advances in Photopletysmography Signal Analysis for Biomedical Applications.

Authors:  Jermana L Moraes; Matheus X Rocha; Glauber G Vasconcelos; José E Vasconcelos Filho; Victor Hugo C de Albuquerque; Auzuir R Alexandria
Journal:  Sensors (Basel)       Date:  2018-06-09       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.