Literature DB >> 21549973

Stresses in the ankle joint and total ankle replacement design.

Rahul Kakkar1, M S Siddique.   

Abstract

The ankle is a highly congruent joint with a surface area of 11-13 cm(2). Total ankle replacements have been attempted since the early 1970s and design has continually evolved as the early designs were a failure. This was because the stresses involved and the mutiaxial motion of the ankle has not been understood until recently. It has been shown that the talus slides as well as rolls during the ankle arc of motion from plantarflexion to dorsiflexion. Furthermore, the articular surfaces and the calcaneofibular and tibiocalcaneal ligaments have been shown to form a four bar linkage dictating ankle motion. A new design ankle replacement has been suggested recently which allows multiaxial motion at the ankle while maintaining congruency throughout the arc of motion. The early results of this ankle replacement have been encouraging without any reported failures due to mechanical loosening.
Copyright © 2011 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 21549973     DOI: 10.1016/j.fas.2011.02.002

Source DB:  PubMed          Journal:  Foot Ankle Surg        ISSN: 1268-7731            Impact factor:   2.705


  8 in total

1.  Analysis of a generic talar prosthetic with a biological talus: A cadaver study.

Authors:  Alexandra N Trovato; Troy D Bornes; Marwan El-Rich; Sukhvinder S Dhillon; Samer Adeeb; Nadr M Jomha
Journal:  J Orthop       Date:  2018-02-03

2.  Deformation of the Titanium Plate Stabilizing the Lateral Ankle Fracture Due to Its Overloading in Case of the Young, Obese Patient: Case Report Including the Biomechanical Analysis.

Authors:  Grzegorz Szczęsny; Mateusz Kopec; Tomasz Szolc; Zbigniew L Kowalewski; Paweł Małdyk
Journal:  Diagnostics (Basel)       Date:  2022-06-16

3.  Bone microarchitecture of the talus changes with aging.

Authors:  Matthias Krause; Martin Rupprecht; Marcus Mumme; Klaus Püschel; Michael Amling; Florian Barvencik
Journal:  Clin Orthop Relat Res       Date:  2013-07-27       Impact factor: 4.176

4.  Patient-specific instrumentation (PSI) in total ankle arthroplasty: a systematic review.

Authors:  Qiuyuan Wang; Nianfei Zhang; Wanshou Guo; Weiguo Wang; Qidong Zhang
Journal:  Int Orthop       Date:  2021-08-04       Impact factor: 3.075

5.  Contact stresses, pressure and area in a fixed-bearing total ankle replacement: a finite element analysis.

Authors:  Nicolo Martinelli; Silvia Baretta; Jenny Pagano; Alberto Bianchi; Tomaso Villa; Gloria Casaroli; Fabio Galbusera
Journal:  BMC Musculoskelet Disord       Date:  2017-11-25       Impact factor: 2.362

Review 6.  Patient-specific instrumentation in total ankle arthroplasty.

Authors:  Antonio Mazzotti; Alberto Arceri; Simone Zielli; Simone Bonelli; Valentina Viglione; Cesare Faldini
Journal:  World J Orthop       Date:  2022-03-18

7.  A new ligament-compatible patient-specific 3D-printed implant and instrumentation for total ankle arthroplasty: from biomechanical studies to clinical cases.

Authors:  C Faldini; A Mazzotti; C Belvedere; G Durastanti; A Panciera; G Geraci; A Leardini
Journal:  J Orthop Traumatol       Date:  2020-09-02

8.  12-year survival analysis of 322 Hintegra total ankle arthroplasties from an independent center.

Authors:  Mina Jane Zafar; Thomas Kallemose; Mostafa Benyahia; Lars Bo Ebskov; Jeannette Østergaard Penny
Journal:  Acta Orthop       Date:  2020-04-14       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.